C O N T R O L P A N E L S
Parameter
Mnemonic
Parameter
Name
Description
Table 1 Default
Value
(Celsius)
Table 2 Default
Value
(Fahrenheit)
Units
sp
Setpoint
Temperature Set Point
46
º
c 115
º
F
Degrees
t
Timer 1
Change Water Cycle
Time
4.00 4.00
H:MM
t
2
Timer 2
Soap Dispensing Delay
Time
2.00 2.00
M:SS
t
3
Timer 3
Soap Dispensing Time
0.30 0.30
M:SS
Al.1
Alarm 1
Alarm 1 Set Point
107
º
c
225
º
F
Degrees
Hs.1
Hysteresis Alarm
1
Hysteresis
0.1 0.1
%
Al..2
Alarm 2
Alarm 2 Set Point
72
º
c 160
º
f
Degrees
Hs..2
Hysteresis
Alarm 2 Hysteresis
0.1 0.1
%
hs
Hysteresis On/Off
Hysteresis
0.1 0.1
%
r
l
Range
Low
Set Point Low Limit
38
º
c 100
º
f
Degrees
r
h
Range
High
Set Point High Limit
52
º
c 125
º
f
Degrees
Setup Mode Parameter Table
Configuration Mode –
c
n
f
Enter the supervisor mode and press the
UP
or
DOWN
buttons until
c
n
f
is displayed.
Press the
TEMP
button to select.
When prompted for a password (
p55
), use the
UP
and
DOWN
buttons to select
415
. Press
the
TEMP
button to enter in the value.
Press the
TEMP
button to toggle between the parameters that are available, see parameter
table below.
The parameter name and its value will be swapped in and out of the display. Press the
UP
and
DOWN
button to change the parameters value. Once a value has been changed, press
the
TEMP
key to lock in this value and move on to the next parameter. If you do not press
the
TEMP
key within three seconds after changing a parameters value, the new value will
not be saved.
Exit the supervisor mode when done with the setup mode.
NOTE:
See Supervisor Mode section
on how to exit.
16
Summary of Contents for Taskmaster PP-3
Page 2: ...Left Blank This Page Intentionally ...
Page 12: ...O P E R A T I O N I N S T R U C T I O N S 11 NOTES ...
Page 48: ...C O N T R O L P A N E L S 47 NOTES ...
Page 52: ...M A I N T E N A N C E 51 NOTES ...
Page 63: ...P A R T S L I S T 62 NOTES ...
Page 64: ...P A R T S L I S T NOTES 63 ...
Page 65: ...P A R T S L I S T NOTES 64 ...
Page 66: ......