C O N T R O L P A N E L S
Sanitize Heater Temperature
This setting sets the water temperature for the Sanitize tank.
Parameter name:
H E A T E R 2 T E M P E R A T U R E
Allowed values:
O F F
, and
1 0 0
e
to
2 0 0
e
(
3 8
d
to
9 3
d
)
Factory default:
O F F
Buzzer Time
This is the time the buzzer will sound when a wash cycle is over.
Parameter name:
B U Z Z E R T I M E
Allowed values:
0 : 0 0
to
9 . 5 9
Factory default:
0 : 1 0
Key Press Buzzer Volume
When a key is pressed, the buzzer can beep for feedback. The volume of this feedback is
adjustable. Note that this does not affect the alarms and other sounds, which remain at
100% volume.
Parameter name:
B U Z Z E R V O L U M E
Allowed values:
0
(no sound) to
4
(loudest)
Factory default:
4
Dry Fire Period
The heater is not used at 100% when trying to detect a dry fire in the OFF state. This
parameter (along with the next one that follows) allows fine-tuning of the heater power.
The period is the time over which the duty cycle is calculated.
Parameter name:
D R Y F I R E P E R I O D
Allowed values:
1 0
to
1 0 0 0
Milliseconds
Factory default:
7 0 0
Dry Fire Duty
The heater is not used at 100% when trying to detect a dry fire. This parameter determines
the duty cycle used.
Parameter name:
D R Y F I R E D U T Y
Allowed values:
1
to
1 0 0
%
Factory default:
6 5
40
Summary of Contents for Taskmaster PP-3
Page 2: ...Left Blank This Page Intentionally ...
Page 12: ...O P E R A T I O N I N S T R U C T I O N S 11 NOTES ...
Page 48: ...C O N T R O L P A N E L S 47 NOTES ...
Page 52: ...M A I N T E N A N C E 51 NOTES ...
Page 63: ...P A R T S L I S T 62 NOTES ...
Page 64: ...P A R T S L I S T NOTES 63 ...
Page 65: ...P A R T S L I S T NOTES 64 ...
Page 66: ......