Installation
1. All models are GRAVITY DRAIN machines equipped with a 2" O.D. hose connection.
2. The maximum flow rate is 15 U.S. gpm/56.8 Lpm.
3. Drain height for all models must not exceed 8-7/8" [225mm] above the finished floor.
4. The drain connection is made to the dishwasher from underneath the machine. An access
hole is provided in the machine base.
NOTE:
DO NOT VENT THE DISHWASHER INTO
WALLS, CEILINGS OR ENCLOSED PLACES.
Ventilation Connections
Drain Connections
2" O.D.
Hose Fitting
Vent
1. The dishwasher is equipped with a vent
stack at the rear of the machine.
2. Typical venting requires a vent hood for the
machine.
3. DO NOT CONNECT A VENT STACK TO
THE DISHWASHER VENT.