134
MAINTENANCE
11. Install the radiator cap.
12. Start the engine and let it idle for several minutes. Stop the engine
and allow it to cool. Check the coolant level in the radiator. If it
is low, add more coolant until it reaches the top of the radiator.
Repeat as necessary.
13. Fill the coolant reservoir with coolant up to the upper limit.
14. Install the coolant reservoir cap and check for coolant leaks. If any
leaks are found, have your dealer check the cooling system.
15. Reinstall the front access cover.
NOTE:
Recommended antifreeze:
Any high quality ethylene glycol antifreeze containing corrosion
inhibitors for aluminum engines.
Antifreeze and water mixing ratio: 1:1
Coolant capacity: CF1000UTR-2(4.2 L),CF800UTR(3.9 L),CF500UTR
(3.5 L).
Coolant change: CF1000UTR-2(4 L),CF800UTR(3.8 L),CF500UTR
(3.4 L).
Coolant reservoir capacity: 380mL ~ 600mL
Cleaning the Radiator
Cleaning the external surfaces of the radiator if it is covered with mud
or debris will ensure it continues to efficiently cool the engine. Use
only low pressure water to clean the radiator. High pressure washers
can damage components. Ensure that water can flow can flow freely
through the radiator fins. This is a sign that cooling air will be allowed
to pass through.