Moreover, there are two control modes responsible for stabilization of the boiler
temperature : Standard and Fuzzy Logic . .
A detailed description of all operating modes and control modes are located ± in the
accompanying s instruction s controller and the burner.
6.6 Cleaning the boiler
WARNING! - SAFETY INFORMATION
Switch the boiler off before cleaning
Wait until the furnace cools down - risk of burns
WARNING! - DANGER OF BURNING !!!
Switch the boiler off before cleaning
Use protective clothing (gloves, goggles)
Wait until the furnace cools down
The boiler can be cleaned of ash using a brush and dustpan or a vacuum cleaner. The manual
presents cleaning of the boiler with a vacuum cleaner. The tool attached to the boiler (brush / rod)
should be used when cleaning the smoke tubes.
Table X - Summary of the frequency of cleaning of individual components
No.
action
Cleaning frequency
1
Ash tank (WO, WZO)
Depending on the quality and quantity of the
burnt pellets - once every 2-6 months
2
Flame tubes
once a month
Front compartment
once a month (WO, WZO, WZO + gp )
once every 2 weeks (W, WZ, WZ + gp )
3
The furnace chamber (W, WZ, WZ + gp )
once a week
4
once every 6 months
once every 6 months
5
Burner
once a week
1.
Emptying the ash container (WO, WZO , WZO + GP )
In order to empty the ash container , lift the handle (1) and pull the container (2) out of the boiler.
Figure 31 - Removing the ash pan
Summary of Contents for QUAD 10
Page 11: ......