2.
Fill the feeder with pellets
In the controller:
Main menu > Manual control > Feeder ON / OFF
Or:
Main menu > Boiler settings > Power modulation> Feeder> Feeder filling> Start
We start the function and wait until the external feeder is filled with pellets .
Figure 28 - Filling the feeder
After filling around the feeder wait until the auger is administered pellet within 2-3 minutes
(in order to properly fill the tray).
For this purpose, it is best to place a container under the downpipe into which the pellets will
fall . Pay attention to the work of the auger - it must work continuously.
3.
Carry out this feeder.
In the controller:
Main menu> Boiler settings> Power modulation> Feeder> Feeder efficiency test>
START
The feeder test lasts 6 minutes, during this time the auger feeds the pellets in a continuous
operation mode . Accordingly, the parameters of pellet dosing during the burner operation are set .
Before the test, pay attention to the whole tray was filled with pellets .
Then perform the test - place a container under the filled device into which the pellets will fall .
Summary of Contents for QUAD 10