3.2. Technical parameters
Tabela I - Zestawienie parametrów technicznych kotła
Parameter
Value
Unit
Boiler
nominal
power
10 , 5
15
twenty
25
thirty
kW
Thermal
power
range
3-10 , 5
4-15
5-20
6-25
7-30
kW
The
required
exhaust draft
MINIMUM 0.15
mbar
Boiler
water
capacity
thirty
41
52
l.
Exhaust
gas
temperature
69.1
66.8
67.2
64.8
62.2
⁰ C
(nominal power)
Exhaust
gas
temperature
53.2
51.4
53.4
52.5
52.7
⁰ C
(minimum power)
Flue gas mass flow
(nominal power)
0.00847 0.0093
0.0115
0.0152
0.0178
kg / s
Flue gas mass flow
(minimum power) 0.00403 0.0044
0.0057
0.0062
0.0073
kg / s
Water
flow
resistance
( nominal power )
0.09
0.08
0.08
mbar
Water
flow
resistance
(minimum power)
0.05
0.01
0.01
Boiler
class according to
EN 303-5: 2012
5
-
Continuous
flammability
(nominal power)
47
31
29
23
24
h
Continuous
flammability
(minimum power)
152
114
114
95
88
h
Temperature
controller setting
range
50-85
⁰ C
Minimum water
temperature
in
the boiler feed
pipe (d)
45
⁰ C
Fuel Type
According to PN-EN-303-5_2012 : C (Pressed wood)