6. Mechanical check
6. Mechanical check
•
•
Move the side switches in position 0 and check the fluency of the motion both in
Move the side switches in position 0 and check the fluency of the motion both in
opening and in closing.
opening and in closing.
Part II : Electrical Connections
Part II : Electrical Connections
The range of motors for the double door is described in the following table:
The range of motors for the double door is described in the following table:
With the motors DWPD, with central profile, the product comes already equipped with
With the motors DWPD, with central profile, the product comes already equipped with
synchronization cable.
synchronization cable.
It is also possible to use 2 single door units (DWP102x) to automate a double leaf door
It is also possible to use 2 single door units (DWP102x) to automate a double leaf door
by the syncronisation of each leaf using the DWPCS serial cable (option).
by the syncronisation of each leaf using the DWPCS serial cable (option).
The cable is terminated with 2 special 3-way connectors and must be inserted in the
The cable is terminated with 2 special 3-way connectors and must be inserted in the
corresponding slot located under the PCB controller of the Digiway (see below).
corresponding slot located under the PCB controller of the Digiway (see below).
Double door total
width
Leaves width
p/n Articulated
Arm
p/n Sliding Arm
p/n Universal
Arm
1600 mm
1600 mm
70 - 80 mm
70 - 80 mm
DWPD10216ACD
DWPD10216ACD
DWPD10216SCD
DWPD10216SCD
DWPD10216UCD
DWPD10216UCD
1700 mm
1700 mm
81 - 85 mm
81 - 85 mm
DWPD10217ACD
DWPD10217ACD
DWPD10217SCD
DWPD10217SCD
DWPD10217UCD
DWPD10217UCD
1800 mm
1800 mm
86 - 90 mm
86 - 90 mm
DWPD10218ACD
DWPD10218ACD
DWPD10218SCD
DWPD10218SCD
DWPD10218UCD
DWPD10218UCD
1900 mm
1900 mm
91 - 95 mm
91 - 95 mm
DWPD10219ACD
DWPD10219ACD
DWPD10219SCD
DWPD10219SCD
DWPD10219UCD
DWPD10219UCD
2000 mm
2000 mm
96 - 100 mm
96 - 100 mm
DWPD10220ACD
DWPD10220ACD
DWPD10220SCD
DWPD10220SCD
DWPD10220UCD
DWPD10220UCD
3
3
Serial cable DWPCS
Serial cable DWPCS
1)
1)
Connect the motors referring to the electrical diagram of the single door.
Connect the motors referring to the electrical diagram of the single door.
WARNING: in the double door mode, with leaves overlapping (rebated), it is very
WARNING: in the double door mode, with leaves overlapping (rebated), it is very
important to identify the type of unit
important to identify the type of unit
•
• MASTER
MASTER unit drives the leaf which opens first and closes last
unit drives the leaf which opens first and closes last
•
• SLAVE
SLAVE unit drives the leaf which opens last and closes first
unit drives the leaf which opens last and closes first
Master
Master
Slave
Slave