DIGIWAY Plus
Inward or Outward Door Operator
21
Parameter
Description
Option
Default
Num. Doors
Sets the number of Doors
ONE DOOR / TWO DOORS
ONE DOOR
Electrolock
Enables electrolock and specify the type
NO LOCK / STRIKE / MAG-
NET
NO LOCK
Opening Jolt
Enables the opening Jolt: SORT CLOSING PULSE BEFORE
OPENING, useful when using an electric strike to stop
binding.
ENABLE / DISABLE
DISABLE
Push & Open
Opens automatically the door with a short push.
ENABLE / DISABLE
ENABLE
Push & Close
Closes the door with a short push even in pause status.
ENABLE / DISABLE
ENABLE
Wind Stop
Keeps the door closed in presence of wind which pushes the
door. See ADVANCED SETTINGS to set the level of the
closing force used.
ENABLE / DISABLE
DISABLE
Autoreclosing
Enables the automatic reclosing of the door
ENABLE / DISABLE
ENABLE
Radar ‘I’ Mode
INTERNAL radar operating mode. If it’s selected the
option CLOSING the radar is excluded during the closing.
This prevents the door reopening if the arm or door is
detected. (*)
NEVER / CLOSING / ALWAYS
NEVER
Radar ‘E’ Mode
EXTERNAL radar operating mode. If it’s selected the
option CLOSING the radar is excluded during the closing.
This prevents the door reopening if the arm or door is de-
tected. (*)
NEVER / CLOSING / ALWAYS
NEVER
Day / Night
Set the Night / Day mode. In Night mode the External radar
is disabled.
DAY & NIGHT / NIGHT
NIGHT
Disabled Mode
Disabled access mode (see paragraph Disabled Access set-
tings)
ENABLE / DISABLE
DISABLE
Open Command
Optional functions for the open command; Open, Close or
Stop. Once selected the function will operate from the open
button (terminals 15 - 16) and the radio transmitter.
OPEN - OPEN/CLOSE -
OPEN-CLOSE/STOP
OPEN/
CLOSE
Spring Mode
If the door is closed it will remain free and can be pushed/
pulled manually; if opened fully the will close after the preset
pause time.
Note: If the door is partially opened up to 75% the pause
time will be 1 sec and will close after .
ENABLE / DISABLE
DISABLE
2 Doors Overlap
Overlap of the leaves (in case of double doors). The MASTER
leaf starts opening first, the SLAVE starts closing first. If
disabled the doors open simultaneously.
ENABLE / DISABLE
DISABLE
Door Type
Leaf MASTER or leaf SLAVE ( in case of double doors )
MASTER / SLAVE
MASTER
Arm Type
Articulated or sliding arm. This parameter set the VELOCITY
of the door according to the arm type selected.
(see Adjustments)
50% ARTICULATED ARM, 70% SLIDING ARM
SLIDING / ARTICULATED
SLIDING
Fire Signal
Fire signal management. When this option is enabled the
door opertates normally if the fire voltage is present V+/V-.
If the fire power is removed(fire alarm triggered) the door
reacts to the option set in the advanced settings.
ENABLE / DISABLE
DISABLE
Step II allows the set up of all the basic parameters of the operator depending on
Step II allows the set up of all the basic parameters of the operator depending on
the door type that is being automated. The submenu CONFIGURATION consists of 18
the door type that is being automated. The submenu CONFIGURATION consists of 18
parameters. Each parameter can have 2 or more values. For each parameter there is
parameters. Each parameter can have 2 or more values. For each parameter there is
a preset factory value. If the function FACTORY DEFAULT of the main menu is used, all
a preset factory value. If the function FACTORY DEFAULT of the main menu is used, all
the parameters are reset to those values.
the parameters are reset to those values.
See the description of each parameter in the following table:
See the description of each parameter in the following table:
STEP II: CONFIGURATION
(*) Please Note: the door must fully close before it can be opened again.