Internal Fuse
The thyristor unit have internal fuse extrarapid at low I
2
t for the thyristor protection of against the short-circuits.
The Fuses must have I²t 20% less than thyristor’s I
2
t. The warranty of thyristor is null if no proper fuses are used.
Size
200 kARMS Symmetrical A.I.C.
Quantity for
each phase
Fuse CODE
Total
Current
(A
RMS
)
FUSE I
2
T value
Suggested A2s
(at 500V)*
FUSE I
2
T value
Suggested A2s
(at 660V)
Vac
60A (S11)
FU2028220.160
160
15400
16940
690
1
90A (S11)
FU2028220.160
160
15400
16940
690
1
120A (S13)
FU2055920.160
160
15400
16940
690
1
150A (S13)
FU2055920.200
200
25000
27500
690
1
180A (S13)
FU2055920.250
250
44000
48400
690
1
210A (S13)
FU2055920.315
315
77000
84700
690
1
300A (S14)
FUFMM400
400
72500
79750
690
1
400A (S14)
FUFMM550
550
215000
236500
690
1
450A (S14)
FUFM315
630
308000
338800
690
2
500A (S14)
FUFM315
630
308000
338800
690
2
600A (S14)
FUFMM450
450
420000
462000
690
2
700A (S14)
FUFMM450
450
420000
462000
690
2
800A (S16)
FU2055920.250
1000
352000
387200
690
4
*I
2
T are multiplied for K value in function of Vac, at 690V K is equal to
1,1 (ex:15400 X 1,1 = 16940). At 660Vac K is equal to 1
Fuses replacement:
Open the cover and remove the screws,
then replace it with the correct fuse, use the screws with a proper
suggested torque indicated below
TYPE
Screw
Torque Lb-in
(N-m)
60A-210A
M6
44.2 (5.0)
300A-800A
M8
133.7(15.0)
Caution:
High speed fuses are used only for the thyristor
protection and can not be used to protect the installation.
Caution:
The warranty of thyristor is null if no proper fuses
are used. See tab.
Warning:
When it is supply, the Thyristor unit is subject to
dangerous voltage, don’t open the Fuse-holder module and
don’t touch the electric equipments.
20
1.2
1.0
0.8
0.6
0.4
0.2
200 400 600 800
1.1
690
Vac
K
(Line voltage)