60
REVO C
2PH from 60A to 800A - 690V
User’s manual
10.6.2 Simple Section
This section is used to create, save, upload and download
recipes of parameters settings. Can be used also to see the
settings in a controller.
Simple page is the default page when select the model using
the Model Button, but If not selected is possible access it
clicking the Simple tab below the main menu.
NOTE!
This section is not “OnLine”
so the parameter
values are not updated continuously. They are read only
when you upload them from the power controller.
To manage recipe click on:
Create a New recipe
: create a recipe fi le with the standard
default settings
Open existing recipe
: open an existing recipe fi le
Upload from unit
: create a new recipe with the value
uploaded from a connected power controller
Close
: close the current recipe
Save
: save the recipe in a fi le
Save as
: save a copy of the recipe in a fi le
Download to unit
: send the current recipe parameters in the connected power
controller
: print the recipe (see sample at right)
Print report
: print the recipe (see sample at right)
To edit the actual recipe values click a parameter menu name:
SETUP
ADVANCED SETUP
HARDWARE
COMMUNICATIONS
and after click on the value and modify it.
NOTE!
Changes to the values here
aff ect the open recipe only. To apply
these changes to the power controller
settings, download them to the power
controller using the Download to unit
option.
Summary of Contents for REVO C 2PH 690V
Page 2: ......