14–Windows Server 2016
Configuring VMMQ
257
BC0154501-00 P
-- --- --------- ----------
0 ETS 5% 0-4,6-7
1 ETS 95% 5
RemoteFlowControl : Priority 5 Enabled
RemoteClassifications : Protocol Port/Type Priority
-------- --------- --------
NetDirect 445 5
Configuring VMMQ
Virtual machine multiqueue (VMMQ) configuration information includes:
Creating a Virtual Machine Switch with or Without SR-IOV
Enabling VMMQ on the Virtual Machine Switch
Getting the Virtual Machine Switch Capability
Creating a VM and Enabling VMMQ on VMNetworkadapters in the VM
Default and Maximum VMMQ Virtual NIC
Enabling and Disabling VMMQ on a Management NIC
NOTE
The preceding example is taken when the adapter port is connected to an
Arista 7060X switch. In this example, the switch PFC is enabled on
Priority 5. RoCE App TLVs are defined. The two traffic classes are defined
as TC0 and TC1, where TC1 is defined for RoCE.
DCBX Protocol
mode is
set to
CEE
. For Arista switch configuration, refer to
“. When the adapter is in
Willing
mode, it accepts
Remote Configuration and shows it as
Operational Parameters
.
NOTE
QoS is also applicable for Windows Server 2012 and Windows Server