17
16
3. Operation
3.1 REG mode Operations
3.1.1 Simple Weighing
There are two types of sales you can generate; PLU Sales and NON-PLU Sales. PLU Sales
are sales based on a programmed PLU whereas Non-PLU Sales are sales you generate
without calling up a PLU.
PLU Sales :
To call up a PLU, simply type the PLU’s number on the Numeric keypad and then press the
PLU key. Another way to call up a PLU is to simply press 1 of 54 preset keys which are set to
a particular PLU.
Press
speed key or press 1 key on the numeric keypad
and PLU key.
Put an item on the
platter.
Press the PRT/* key.
Enter a unit price.
Place the commodity
on the platter.
Press the PRT/* key.
NON-PLU Sales:
3.1.2 How to Use TARE
Known Tare:
If you know the weight of container you may use this method to enter the tare.
For example, if the weight of the container is 10g press the 1, 0, and TARE key. Call up a
PLU and place a commodity then you will see the net weight.
Unknown Tare:
If you do not know the weight of the container you may use this method. Place the container
on the platter and press the TARE key. Call up a PLU and place the commodity on the platter
then you will see the net weight.
Releasing the Tare
To release the tare, remove all items from the platter and then press the TARE key.
3.1.3 Add-up Sales
Call up a PLU and put an item on the platter.
You can add up non-PLU item. Enter a unit price and place an item on the
platter. If you want to add up.
press the + key.
Remove an item
from the platter
If you want to add up this item.
press the + key. You will have a label automatically.