GB
// 72
Audible alarm
1. When the transmitter battery is low and the voltage is lower
than 3.75V, the system will make alarm which sounds slowly.
2. If the voltage is lower than setting data due to low battery of
receiver, the system will make a sound „Ba, Ba“.
3. When the error rate is more than 60%, the system will make a
sound „Du, Du“.
4. When the timer goes off, the system will make a sound “Bi, Bi, Bi,
Bi’” thrice.
5. Before the transmitter is turned off automatically, the system
will make a sound „Du Du Du“.
6. When the transmitter’s battery voltage is lower than 3.7 V,
the system will make alarm which sounds quickly. When the
voltage is lower than 3.65 V, the transmitter will be turned off
automatically.
1. Transmitter does not start up.
• The battery is not properly installed.
• Battery is empty.
• The screen flashes when the transmitter is powered on, and
then the transmitter turn itself off immediately. It indicates the
electric quantity can´t support system for a long time and the
transmitter will be turned off once it is powered on.
• The battery shrapnel is oxidized and loose contact.
2. Remote control distance is not enough.
• The wrong position of transmitter antenna or receive antenna.
• Nearby radio interference.
• Battery is empty.
• Obstacle screens off part of the signal.
3. The transmitter can´t control the receiver.
• The transmitter or receiver enters into the bound status by
accident. The problem can be solved by powering on again or
binding again if necessary.
4. The transmitter may not accept the data sent by the
receiver sometimes when many people race at the same
time.
• The distance between two transmitters is too close. Please keep
more than 5 meters as far as possible.
5. The item number of acquisition module does not appear in
the transmitter screen.
• The data cable of acquisition module is connected to the wrong
places.
• The plug of data cable is damaged.
6. The unstable data of speed acquisition.
• The position of speed sensor is not proper, which drifts too far.
7. The simulator can not be checked on the computer.
• The USB simulator function of transmitter is not activated.
LED indicator alarm
LED indicator alarm function synchronizes with audible alarm
function. It has no effect on LED indicator after turning off the
audible alarm.
Please check as folIows:
1. The LED remains on: all functions are normal
2. The LED flashes slowly: the transmitter battery is low.
3. The LED flash is quickly:
- The battery of the transmitter is very low.
- Error rate is more than 60%.
- The battery of receive is low.
- The transmitter will turn itself off soon.
4. LED indicator is off: power off.
Alarm function description
Problem solving