he specific technical features of each DB-S model are indicated on the data
plate attached to the unit (fig. 3).
T
he DB-S range includes air condensed refrigerating units designed and manufactu-
red to operate automatically. Using the machine for any purposes other than those
envisaged represents an anomaly and may seriously endanger people’s safety.
3.1 Dangers deriving from using the
The unit is not designed to operate in premises where explosives are stored.
unit for purposes other than
Therefore, it is categorically forbidden to use it in locations where any risk of
those it is designed for
explosion exists.
Should the user wish to use the unit for any purposes or in any fields other than
those intended (see ch. 8, section 8.2 of this manual), or wish to modify the unit
in any way, he should consult the manufacturer/distributor about any contraindi-
cations or dangers that may derive from the incorrect use of the unit.
1.4
1.4
RESIDUAL
RESIDUAL
RISKS
RISKS
22..
22..
TTEEC
CH
HN
NIIC
CA
ALL FFEEA
ATTUURREESS O
OFF TTH
HEE UUN
NIITT
TTEEC
CH
HN
NIIC
CA
ALL FFEEA
ATTUURREESS O
OFF TTH
HEE UUN
NIITT
fig.3
Mod.
Mod.
Matricola
Serial Number
Tensione
Voltage
Assorb. Marcia
Run Absorption
Refrigerante
Refrigerant
Massa C
Mass C
A
Kw
Kg
Via Martin L. King, nr. 30
46020 PEGOGNAGA
(Mantova) - Italy
ZANOTTI
SS..pp..AA..
Modello
Model
Potenza compressore
Compressor power
A
Assorb. Max
Max Absor.
Kw
Schemi
Diagr.
1) Anno di costruzione
2) Codice unità "CARRIER"
3) Numero matricola
4) Tensione
5) Assorbimento Marcia (Macchina)
6) Assorbimento massimo
7) Assorbimento di spunto (Macchina all' avviamento)
8) Potenza nominale compressore
9) Refrigerante : Tipo ; Quantità
10) Massa macchina
11) Numero schema elettrico (Progetto)
Carrier Refrigeration AB
A
Ass. Spunto
Start. Abs.
Kg
Massa E
Mass E
Kg
33..
33..
IIN
NTTEEN
ND
DEED
D UUSSEESS
IIN
NTTEEN
ND
DEED
D UUSSEESS
1) Year of manufacture
2) CARRIER unit code
3) Serial number
4) Voltage
5) Operating current
6) Maximum current
7) Starting current
8) Compressor’s nominal power
9) Refrigerating liquid Type; Quantity
10) Mass of the unit
11) Electric diagram (Project) number
Below we list all the situations - from the delivery of the unit to its demolition
- in which the user will need to exercise caution in order to avoid damage to
persons.
CHAPTER 4
- Positioning the unit
Maximum caution should be used in ensuring that no one passes through
the area while the suspended load is being handled, in order to avoid any
chance of damage to persons.
CHAPTER 9
- Maintenance
Condenser and evaporator groups’ fins: any maintenance operations must
be carried out using personal protection devices (e.g. gloves) in order to
avoid any chance of damage to hands.