COOLING CHARGING CHARTS
Table 2 – Single Compressor
Position 6 = A
Unit
Size
Reference
Tons
Fig.
No.
Figure Title
Source Drw Nbr -- Rev
04
3 Tons
23
Charging Chart, 48TC Size A04
48TM500231 Rev 3.0
05
4 Tons
24
Charging Chart, 48TC Size A05
48TM500232 Rev 3.0
06
5 Tons
25
Charging Chart, 48TC Size A06
48TM500233 Rev 3.0
07
6 Tons
26
Charging Chart, 48TC Size A07
48TM500234 Rev 3.0
08
7.5 Tons
27
Charging Chart, 48TC Size A08
48TM500885 Rev 3.0
09
8.5 Tons
28
Charging Chart, 48TC Size A09
48TM500886 Rev 3.0
12
10 Tons
29
Charging Chart, 48TC Size A12
48TM500887 Rev 3.0
Table 3 – Two Compressor Models
Position 6 = D or E
Unit
Size
Reference
Tons
Fig.
No.
Figure Title
Source Drw Nbr – Rev
08
7.5 Tons
30
Charging Chart, 48TC Size D,E08
48TM501445 Rev 3.0
09
8.5 Tons
31
Charging Chart, 48TC Size D,E09
48TM502362 Rev 2.0
12
10 Tons
32
Charging Chart, 48TC Size D,E12
48TM501446 Rev 3.0
14
12.5 Tons
33
Charging Chart, 48TC Size D,E14
With Round Tube Plate Fin Coil
(Position 11 = A B,C,D,E,F,M,N,P,Q,R,S)
RT 48TM502601 Rev A
34
Charging Chart, 48TC Size D14
With NOVATION Coil
(
Position 11 = G,H,J,K,L,T,U,V,W,X)
MC 48TM501842 Rev 2
16
15 Tons
35
Charging Chart, 48TC Size D16
50TM501081 Rev A
Charging Chart, 48TC Size E16
Humidi-MiZer
50TM501081 Rev. A
Table 4 – Single Compressor with Humidi--Mizer
Position 6 = B
Unit
Size
Reference
Tons
Fig.
No.
Figure Title
Source Drw Nbr -- Rev
04
3 Tons
36
Charging Chart, 48TC Size B04
Humidi-MiZer in Reheat1
48TM501619 Rev 02
05
4 Tons
37
Charging Chart, 48TC Size B05
Humidi-MiZer in Reheat1
48TM501865 Rev 02
06
5 Tons
38
Charging Chart, 48TC Size B06
Humidi-MiZer in Reheat1
48TM501866 Rev 02
07
6 Tons
39
Charging Chart, 48TC Size B07
Humidi-MiZer in Reheat1
48TM501867 Rev 02
48TC
Summary of Contents for 48TC 04 Series
Page 27: ...27 COOLING CHARGING CHARTS cont C14064 Fig 33 Cooling Charging Charts 12 5 Ton 48TC...
Page 29: ...29 COOLING CHARGING CHARTS cont C13218 Fig 35 Charging Chart 48TC Size D16 48TC...
Page 40: ...40 C14052 Fig 51 Typical Smoke Detector System Wiring 48TC...
Page 122: ...122 APPENDIX III WIRING DIAGRAMS C12413 Fig 103 48TC A04 A07 Power Diagram 208 230 1 60 48TC...
Page 124: ...124 APPENDIX III WIRING DIAGRAM LIST C12415 Fig 105 48TC A04 A07 Power Diagram 575 3 60 48TC...
Page 126: ...126 APPENDIX III WIRING DIAGRAM LIST C13246 Fig 107 48TC A08 A12 Power Diagram 575 3 60 48TC...
Page 128: ...128 APPENDIX III WIRING DIAGRAM LIST C13247 Fig 109 48TC D08 D12 Power Diagram 575 3 60 48TC...
Page 130: ...130 APPENDIX III WIRING DIAGRAM LIST C13249 Fig 111 48TC D14 Power Diagram 575 3 60 48TC...
Page 139: ...139 APPENDIX III WIRING DIAGRAMS C12423 Fig 120 48TC D16 Power Diagram 575 3 60 48TC...
Page 143: ...143 APPENDIX III WIRING DIAGRAM LIST C13485 Fig 124 48TC 16 PremierLink Control Diagram 48TC...
Page 145: ...145 APPENDIX III WIRING DIAGRAM LIST C13487 Fig 126 48TC 16 RTU Open Control Diagram 48TC...
Page 146: ...146 APPENDIX III WIRING DIAGRAM LIST C14124 Fig 127 48TC D08 14 E08 14 W7220 2 Speed IFM 48TC...