MODEL NOMENCLATURE
Coil Options For Round Tube/Plate Fin Condenser Coil Models Only (outdoor-
indoor-hailguard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu - Al/Cu – Louvered Hail Guards
N = Precoat Al/Cu - Al/Cu – Louvered Hail Guards
P = E-coat Al/Cu - Al/Cu – Louvered Hail Guards
Q = E-coat Al/Cu - E-coat Al/Cu – Louvered Hail Guards
R = Cu/Cu - Al/Cu – Louvered Hail Guards
S = Cu/Cu - Cu/Cu – Louvered Hail Guards
Coil Options For All Aluminum – Novation Condenser Coil Models Only
(outdoor-indoor-hailguard)
G = Al/Al – Al/Cu
H = Al/Al – Cu/Cu
J = Al/Al – E-coat Al/Cu
K = E-coat Al/Al – Al/Cu
L = E-coat Al/Al – E-coat Al/Cu
T = Al/Al – Al/Cu, Louvered Hail Guards
U = Al/Al – Cu/Cu, Louvered Hail Guards
V = Al/Al – E-coat Al/Cu, Louvered Hail Guards
W = E-coat Al/Al – Al/Cu, Louvered Hail Guards
X = E-coat Al/Al – E-coat Al/Cu, Louvered Hail Guards
4
8
T
C
D
A
0
4
A
1
A
5
-
0
A
0
A
0
Unit Heat Type
48 – Gas Heat
Packaged
Rooftop
Series/Model
TC – Standard Efficiency
Heat Size
D – Low heat
E – Medium Heat
F – High Heat
L – Low NO
x
, Low Heat
M – Low NO
x
, Medium Heat
N – Low NO
x
, High Heat
S – Stainless Steel, Low Heat
R – Stainless Steel, Medium Heat
T – Stainless Steel, High Heat
Refrig. Systems Options
A - Standard One Stage Cooling Models
B – Standard One Stage Cooling Models
with Humidi-MiZer (04-07 models only)
D – Two Stage Cooling Models 08-16
E – Two Stage Cooling Models 08-16
with Al/Cu condenser Coils and
with Humidi-MiZer
Cooling Tons
04 - 3 ton 08 – 7.5 ton 16 – 15 Tons
05 - 4 ton 09 – 8.5 ton
06 - 5 ton 12 – 10 ton
07 - 6 ton 14 – 12.5 ton
Packaging and Seismic Compliant
0 = Standard
1 = LTL
3 = CA Seismic Compliant
4 = LTL and CA Seismic Compliant Label
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and Thru-The-Base Connections
G = 2-Speed Indoor Fan (VFD) Controller
J = 2 Speed Fan Controller (VFD) and Non-Fused Disconnect
K = 2 Speed Fan Controller (VFD) and Thru-The Base Connections
M = 2 Speed Fan Controller (VFD) with Non-Fused Disconnect and
Thru-The Base Connections
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels, Unpowered Convenience Outlet
5 = Hinged Panels, Powered Convenience Outlet
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = 2-Position Damper
U = Temp Ultra Low Leak Economizer w/Baro Relief
W = Enthalpy Ultra Low Leak Econo w/Baro Relief
Base unit controls
0 = Electromechanical Controls. Can be used with W7212 EconoMi$er IV
(factory or field installed)
1 = PremierLink Controller
2 = RTU Open Multi-Protocol Controller
6 = Electromechanical Controls. Can be used with W7220 EconoMi$er X
(factory or field installed)
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO2 Sensor
F = RA Smoke Detector and CO2 Sensor
G = SA Smoke Detector and CO2 Sensor
H = RA + SA Smoke Detector and CO2 Sensor
Indoor Fan Options
1 = Standard Static Option
2 = Medium Static Option
3 = High Static Option
C = High Static Option w/ High Effy Motor (Size 16 Only)
Design Revision
Factory Assigned
Voltage
1 = 575/3/60 5 = 208-230/3/60
3 = 208-230/1/60
6 = 460/3/60
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 18
Note: On single phase (-3 voltage code) models, the following
are not available as a factory installed option:
- Humidi-Mizer
- Coated Coils or Cu Fin Coils
- Louvered Hail Guards
- Economizer or 2 Position Damper
- Powered 115 Volt Convenience Outlet
Not all possible options can be displayed above.
C13211B
48TC
Summary of Contents for 48TC 04 Series
Page 27: ...27 COOLING CHARGING CHARTS cont C14064 Fig 33 Cooling Charging Charts 12 5 Ton 48TC...
Page 29: ...29 COOLING CHARGING CHARTS cont C13218 Fig 35 Charging Chart 48TC Size D16 48TC...
Page 40: ...40 C14052 Fig 51 Typical Smoke Detector System Wiring 48TC...
Page 122: ...122 APPENDIX III WIRING DIAGRAMS C12413 Fig 103 48TC A04 A07 Power Diagram 208 230 1 60 48TC...
Page 124: ...124 APPENDIX III WIRING DIAGRAM LIST C12415 Fig 105 48TC A04 A07 Power Diagram 575 3 60 48TC...
Page 126: ...126 APPENDIX III WIRING DIAGRAM LIST C13246 Fig 107 48TC A08 A12 Power Diagram 575 3 60 48TC...
Page 128: ...128 APPENDIX III WIRING DIAGRAM LIST C13247 Fig 109 48TC D08 D12 Power Diagram 575 3 60 48TC...
Page 130: ...130 APPENDIX III WIRING DIAGRAM LIST C13249 Fig 111 48TC D14 Power Diagram 575 3 60 48TC...
Page 139: ...139 APPENDIX III WIRING DIAGRAMS C12423 Fig 120 48TC D16 Power Diagram 575 3 60 48TC...
Page 143: ...143 APPENDIX III WIRING DIAGRAM LIST C13485 Fig 124 48TC 16 PremierLink Control Diagram 48TC...
Page 145: ...145 APPENDIX III WIRING DIAGRAM LIST C13487 Fig 126 48TC 16 RTU Open Control Diagram 48TC...
Page 146: ...146 APPENDIX III WIRING DIAGRAM LIST C14124 Fig 127 48TC D08 14 E08 14 W7220 2 Speed IFM 48TC...