57
Table 20 – Altitude Compensation* Models 48TC08--14 (D, E, F, S, R, T)
NATURAL GAS
ELEVATION
NOMINAL HEAT INPUT
72k BTUH
125k BTUH
150k BTUH
180k BTUH
224k BTUH
250k BTUH
FT
M
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
0 --- 2000
0 --- 610
33
1
72,000
31
1
125,000
32
1
150,000
31
1
180,000
31
1
224,000
†30
250,000
2000
610
35
1
66,240
32
1
115,000
33
1
138,000
32
1
165,600
32
1
206,080
†30
230,000
3000
914
35
1
63,360
32
1
110,000
35
1
132,000
32
1
158,400
32
1
197,120
31
1
220,000
4000
1219
36
1
60,480
33
1
105,000
35
1
126,000
33
1
151,200
33
1
188,160
31
1
210,000
5000
1524
36
1
57,600
33
1
100,000
35
1
120,000
33
1
144,000
33
1
179,200
31
1
200,000
6000
1829
37
2
54,720
35
1
95,000
36
1
114,000
33
1
136,800
33
1
170,240
31
1
190,000
7000
2134
38
2
51,840
35
1
90,000
36
1
108,000
35
1
129,600
35
1
161,280
32
1
180,000
8000
2438
38
2
48,960
36
1
85,000
36
1
102,000
36
1
122,400
36
1
152,320
33
1
170,000
9000
2743
†40
46,080
37
2
80,000
37
2
96,000
37
2
115,200
37
2
143,360
33
1
160,000
10000
3048
†41
43,200
38
2
75,000
38
2
90,000
38
2
108,000
38
2
134,400
35
1
150,000
11000
3353
†42
40,320
39
2
70,000
†40
84,000
39
2
100,800
39
2
125,440
36
1
140,000
12000
3658
†42
37,440
†41
65,000
†40
78,000
†41
93,600
†41
116,480
37
2
130,000
13000
3962
†43
34,560
†42
60,000
†41
72,000
†42
86,400
†42
107,520
38
2
120,000
14000
4267
†43
31,680
†43
55,000
†41
66,000
†43
79,200
†43
98,560
†40
110,000
* As the height above sea level increases, there is less oxygen per cubic ft. of air. Therefore, heat input rate should be reduced at higher altitudes.
{
Not included in kit. May be purchased separately through dealer.
ORIFICE
XX
1
XX
2
XX
3
XX
4
ACC. KIT PN
CRLPELEV001A00
CRLPELEV002A00
CRLPELEV003A00
CRLPELEV004A00
PROPANE GAS
Table 21 – Altitude Compensation* Models 48TC08--14 (D, E, F, S, R, T)
ELEVATION
NOMINAL HEAT INPUT
72k BTUH
125k BTUH
150k BTUH
180k BTUH
224k BTUH
250k BTUH
FT
M
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
Orifice
Size
Input
(btu/hr)
0 --- 2000
0 --- 610
51
4
72,000
49
3
125,000
50
3
150,000
48
3
180,000
48
3
224,000
46
3
250,000
2000
610
51
4
66,240
50
3
115,000
51
4
138,000
49
3
165,600
49
3
206,080
47
3
230,000
3000
914
52
4
63,360
50
3
110,000
51
4
132,000
49
3
158,400
49
3
197,120
47
3
220,000
4000
1219
52
4
60,480
50
3
105,000
51
4
126,000
49
3
151,200
49
3
188,160
48
3
210,000
5000
1524
52
4
57,600
51
4
100,000
51
4
120,000
50
3
144,000
50
3
179,200
48
3
200,000
6000
1829
52
4
54,720
51
4
95,000
52
4
114,000
50
3
136,800
50
3
170,240
48
3
190,000
7000
2134
53
4
51,840
51
4
90,000
52
4
108,000
50
3
129,600
50
3
161,280
49
3
180,000
8000
2438
53
4
48,960
52
4
85,000
52
4
102,000
51
4
122,400
51
4
152,320
49
3
170,000
9000
2743
53
4
46,080
52
4
80,000
53
4
96,000
51
4
115,200
51
4
143,360
50
3
160,000
10000
3048
54
4
43,200
52
4
75,000
53
4
90,000
52
4
108,000
52
4
134,400
50
3
150,000
11000
3353
54
4
40,320
53
4
70,000
53
4
84,000
52
4
100,800
52
4
125,440
51
4
140,000
12000
3658
54
4
37,440
53
4
65,000
53
4
78,000
53
4
93,600
53
4
116,480
51
4
130,000
13000
3962
55
4
34,560
54
4
60,000
53
4
72,000
53
4
86,400
53
4
107,520
52
4
120,000
14000
4267
55
4
31,680
54
4
55,000
55
4
66,000
54
4
79,200
54
4
98,560
53
4
110,000
* As the height above sea level increases, there is less oxygen per cubic ft. of air. Therefore, heat input rate should be reduced at higher altitudes.
{
Not included in kit. May be purchased separately through dealer.
ORIFICE
XX
1
XX
2
XX
3
XX
4
ACC. KIT PN
CRLPELEV001A00
CRLPELEV002A00
CRLPELEV003A00
CRLPELEV004A00
48TC
Summary of Contents for 48TC 04 Series
Page 27: ...27 COOLING CHARGING CHARTS cont C14064 Fig 33 Cooling Charging Charts 12 5 Ton 48TC...
Page 29: ...29 COOLING CHARGING CHARTS cont C13218 Fig 35 Charging Chart 48TC Size D16 48TC...
Page 40: ...40 C14052 Fig 51 Typical Smoke Detector System Wiring 48TC...
Page 122: ...122 APPENDIX III WIRING DIAGRAMS C12413 Fig 103 48TC A04 A07 Power Diagram 208 230 1 60 48TC...
Page 124: ...124 APPENDIX III WIRING DIAGRAM LIST C12415 Fig 105 48TC A04 A07 Power Diagram 575 3 60 48TC...
Page 126: ...126 APPENDIX III WIRING DIAGRAM LIST C13246 Fig 107 48TC A08 A12 Power Diagram 575 3 60 48TC...
Page 128: ...128 APPENDIX III WIRING DIAGRAM LIST C13247 Fig 109 48TC D08 D12 Power Diagram 575 3 60 48TC...
Page 130: ...130 APPENDIX III WIRING DIAGRAM LIST C13249 Fig 111 48TC D14 Power Diagram 575 3 60 48TC...
Page 139: ...139 APPENDIX III WIRING DIAGRAMS C12423 Fig 120 48TC D16 Power Diagram 575 3 60 48TC...
Page 143: ...143 APPENDIX III WIRING DIAGRAM LIST C13485 Fig 124 48TC 16 PremierLink Control Diagram 48TC...
Page 145: ...145 APPENDIX III WIRING DIAGRAM LIST C13487 Fig 126 48TC 16 RTU Open Control Diagram 48TC...
Page 146: ...146 APPENDIX III WIRING DIAGRAM LIST C14124 Fig 127 48TC D08 14 E08 14 W7220 2 Speed IFM 48TC...