62
Tag
Parameter Name
Min
Max
ICR
RO
Preset
Menu Block
User
64
Frequency Input Term 18 0% Calibration
0 Hz
60000 Hz
0 Hz
Frequency Input
65
Frequency Input Term 18 100% Calibration
0 Hz
60000 Hz
40000 Hz
Frequency Input
66
Frequency Input Term 18 Bias
0.00%*
200.00%*
0.00%
Frequency Input
67
Frequency Input Term 18 Gain
0.00%*
200.00%*
100.00%
Frequency Input
68
Frequency Input Term 18 filtering
0
15
0
Frequency Input
69
User Relay 1 Term 25-27 Source
0
500
ICR
210
User Relay
70
User Relay 2 Term 28-30 Source
0
500
ICR
242
User Relay
71
User Relay 3 Term 54-56 Source
0
500
ICR
303
User Relay
72
User Relay 1 Term 25-27 Absolute Value
0:False
1:True
1:True
User Relay
73
User Relay 2 Term 28-30 Absolute Value
0:False
1:True
1:True
User Relay
74
User Relay 3 Term 54-56 Absolute Value
0:False
1:True
1:True
User Relay
75
User Relay 1 Term 25-27 On Value
0:False*
1:True*
1:True
User Relay
76
User Relay 2 Term 28-30 On Value
0:False*
1:True*
1:True
User Relay
77
User Relay 3 Term 54-56 On Value
0:False*
1:True*
1:True
User Relay
78
User Relay 1 Term 25-27 Off Value
0:False*
1:True*
0:False
User Relay
79
User Relay 2 Term 28-30 Off Value
0:False*
1:True*
0:False
User Relay
80
User Relay 3 Term 54-56 Off Value
0:False*
1:True*
0:False
User Relay
81
Analog Output 1 Term 21 Source
0
500
ICR
193
Analog Output
82
Analog Output 2 Term 22 Source
0
500
ICR
102
Analog Output
83
Analog Output 1 Term 21 Gain
-200.00%
200.00%
100.00%
Analog Output
84
Analog Output 2 Term 22 Gain
-200.00%
200.00%
100.00%
Analog Output
85
Analog Output 1 Term 21 Bias
-100.00%
100.00%
0.00%
Analog Output
86
Analog Output 2 Term 22 Bias
-100.00%
100.00%
0.00%
Analog Output
87
Analog Output 1 Term 21 Absolute Value
0:False
1:True
0:False
Analog Output
88
Analog Output 2 Term 22 Absolute Value
0:False
1:True
0:False
Analog Output
89
Freq/Digital Output Term 52 Source
0
500
ICR
193
F/D Output
90
Frequency/Digital Term 52 Mode
0:Freq
1:Digital
0:Freq
F/D Output
91
Digital Output Term 52 Absolute Value
0:False
1:True
1:True
F/D Output
92
Digital Output Term 52 On Value
-200.00%*
200.00%*
100.00%
F/D Output
93
Digital Output Term 52 Off Value
-200.00%*
200.00%*
0.00%
F/D Output
94
Digital Output Term 52 Invert
0:False
1:True
0:False
F/D Output
95
Frequency Output Term 52 Gain
0.00%
200.00%
100.00%
F/D Output
96
Frequency Output Term 52 Bias
0.00%
100.00%
0.00%
F/D Output
97
Torque Reference
-150.00%
150.00%
0.00%
Current Loop
98
Aux Current Demand
-150.00%
150.00%
0.00%
Current Loop
99
Positive C.L.
0.00%
150.00%
150.00%
Current Loop
100
Negative C.L.
-150.00%
0.00%
-150.00%
Current Loop
101
Final Current Demand
-150.00%
150.00%
RO
0.00%
Current Loop
102
Current Feedback
-150.00%
150.00%
RO
0.00%
Current Loop
103
Current Error
-300.00%
300.00%
RO
0.00%
Current Loop
104
Open Loop Arm Select
0:False
1:True
ICR
0:False
Current Loop
105
Open Loop Arm Set Pt
-100.00%
100.00%
0.00%
Current Loop
106
Conduction Angle Demand
0.00%
100.00%
RO
0.00%
Current Loop
107
Current Proportional Gain
0.00
25.00
2.50
Current Loop
108
Current Integral Time
0.010 Secs
30.000 Secs
0.164 Secs
Current Loop
109
Drive Mode (MSB)
0
1
0
Current Loop
110
Drive Mode (LSB)
0
1
0
Current Loop
111
Current Demand
-150.00%
150.00%
RO
0.00%
Current Loop
112
Current Feedback {Filtered}
-150.00%
150.00%
RO
0.00%
Current Loop
113
Final Current Demand {Filtered}
-150.00%
150.00%
RO
0.00%
Current Loop
114
Armature Amps
0.0 Amps
1530.0 Amps
RO
0.0 Amps
Current Loop
115
Aux 1 Param
-200.00%
200.00%
0.00%
Misc Aux Params
116
Aux 2 Param
-200.00%
200.00%
0.00%
Misc Aux Params
117
Aux 3 Param
-200.00%
200.00%
0.00%
Misc Aux Params
118
Aux 4 Param
-200.00%
200.00%
0.00%
Misc Aux Params
119
Aux 5 Param
-200.00%
200.00%
0.00%
Misc Aux Params
120
Aux 6 Param
-200.00%
200.00%
0.00%
Misc Aux Params
121
Aux 7 Param
-200.00%
200.00%
0.00%
Misc Aux Params
122
Nameplate Drive Current
Per Model
Per Model
RO
Per Model
Calibration
123
Nameplate Motor Current
0.0 Amps
Per Model
Per Model
Calibration
124
Encoder Lines
0:256,1:512,2:1024,3:2048
2:1024
Calibration
125
100% Encoder RPM
0 RPM
10000 RPM
1750 RPM
Calibration
126
Invert FB
0:False
1:True
0:False
Calibration
127
Tachometer Type
0:DC
1:AC
0:DC
Calibration
128
Nameplate Motor Voltage
0.0 Volts
500.0 Volts
240.0 Volts
Calibration
129
Final Velocity Demand
-105.00%
105.00%
RO
0.00%
Velocity Loop
130
VFB Offset
-10.00%
10.00%
0.00%
Velocity Loop
131
IR Compensation
0.00%
10.00%
0.00%
Velocity Loop
132
Digital Input 1 Term 31 Status
0:Open
1:Closed
RO
0:Open
Digital Input
133
Digital Input 2 Term 32 Status
0:Open
1:Closed
RO
0:Open
Digital Input
Summary of Contents for Elite Pro EPN020-000
Page 10: ...10 Figure 4 ...
Page 80: ...80 Prints ...
Page 81: ...81 ...
Page 82: ...82 ...
Page 83: ...83 ...
Page 85: ...85 ...
Page 88: ...88 ...
Page 89: ...89 ...
Page 90: ...90 ...
Page 91: ...91 ...
Page 92: ...92 ...
Page 93: ...93 ...
Page 94: ...94 ...
Page 95: ...95 ...
Page 96: ...96 ...
Page 97: ...97 ...
Page 98: ...98 ...
Page 99: ...99 ...
Page 100: ...100 ...
Page 101: ...101 ...
Page 102: ...102 ...
Page 103: ...103 ...
Page 104: ...104 ...
Page 105: ......
Page 106: ...106 PRO SOFT ...
Page 107: ...107 WARE BLOCK DIAGRAM ...
Page 108: ...108 ...