background image

PLEASE REVIEW ALL WARNING INSTRUCTIONS PRIOR TO OPERATION. SAVE THIS MAN U AL FOR FUTURE REF ER ENCE.

Rev. 09/11/18

6-1138

2

FAILURE TO OBSERVE THESE WARNINGS COULD RE SULT IN IN JU RY.

WARNING

wear jew el ry or loose clothing. Se cure 

long hair. Scalp ing can occur if hair is 

not kept away from tool and ac 

ces­

so 

ries. Chok 

ing can oc 

cur if neck­

wear is not kept away from tool and 

 

ac ces so ries.

   

• This tool is not insulated 

   

against electric shock.

   

• This tool must not be used 

   

in explosive atmospheres.

   

• Do not lubricate tools with 

   

  flammable or volatile liquids 

 

   

 such as kerosene, diesel 

   

  or jet fuel.

• Impact wrenches are not torque 

 

 

con trol  devices.  Fas ten ers  with 

 

spe cif ic  torque  re quire ments  must  be 

 checked with suit 

able torque 

 

measuring  de vic es  after  in stal la tion 

  with an im pact wrench.

• Use only impact sockets and 

  accessories on this tool.  Do not 

  use hand and/or chrome sockets 

  and accessories.  

• Do not force tool be 

yond its 

 

 

rat ed  capacity.

• Do not remove any labels. 

 

  Re place any damaged labels.

•  Use  accessories  rec om mend ed  by 

  NAPA Professional Air Tools.

•  Servicing and repairs should only be 

  made by an authorized service center.
•  Do not use (or modify) the tool for 

  any other purpose than that for which 

  it was designed without consulting the 

 manufacturer's 

authorized 

 representative.
•  Failure to heed these warnings may 

  result in serious or fatal personal injury 

  and/or property damage.

   WARNING:

 This product 

   

can expose you to chemicals 

    including nickel, which is 

known to the State of California 

to cause cancer and birth defects 

or other reproductive harm. 

For more information go to 

www.P65Warnings.ca.gov.

   THIS  INSTRUCTION  MAN U AL 

 

 

CON TAINS  IMPORTANT 

   

SAFETY INFORMATION. 

READ  THIS  IN STRUC TION 

MANUAL  CARE FUL LY  AND 

UN DER STAND  ALL  IN FOR MA TION 

BE FORE    OP ER AT ING  THIS  TOOL.

It is the responsibility of the owner 

to make sure all personnel read this 

manual prior to using the device. It is 

also the responsibility of the device 

owner to keep this manual intact & in 

a convenient location for all to see & 

read.  If the manual or product labels 

are lost or not  legible, contact NAPA for 

replacements. If the operator is 

not fluent in English, the product & 

safety instructions shall be read 

& discussed with the operator in 

the operator's native language 

by the purchaser/owner or his 

designee,making sure that the operator 

comprehends its contents.
• Al 

ways operate, in 

spect and 

  main 

tain this tool in ac 

cor 

dance 

 

with  Amer i can  Na tion al  Stan dards 

 

In sti tute  Safe ty  Code  of  Por ta ble 

  Air Tools (ANSI B186.1) and any 

 

oth er  ap pli ca ble  safe ty  codes  and 

 

reg u la tions.

 

 

• 

For safety, top 

    perfor mance  and  maxi mum 

 

 

  du ra bil i ty  of  parts,  op er ate 

this tool at 90 psig, 6.2 bar max 

air pres 

sure with 3/8" di 

am 

ter air 

sup ply  hose.

 

  • 

Always wear impact 

    

resistant eye & face 

 

   

protection (Users & 

Bystanders) when operating or 

performing maintenance on this tool . 

   • 

Always wear hearing 

   protection 

when using this tool 

   

(Users & Bystanders).  High 

   sound levels can cause 

permanent hearing loss.  Use hearing 

protection as recommended by your 

employer or OSHA regulation.
•  Keep the tool in efficient operating 

 condition.
•  Operators 

and 

main te nance 

per son nel  must  be  phys i cal ly  able  to 

han dle the bulk, weight and pow er of 

this tool.
•  Keep tool our ot reach of children.

 

  • 

Air­powered tools can 

   

vibrate during use.  Extended 

   

exposure to vibration, repetitive 

motions, or uncomfortable positions during 

use may be harmful to your hands and 

arms.  Discontinue use of tool if discomfort, 

tingling, or pain occurs.  Seek medical 

advice before resuming use.

   

• Compressed air can cause 

   

severe injury.  Never direct 

   air at yourself or others. 

 

   

Always turn off the air supply, 

   

drain hose of air pressure, 

   and detach tool from air 

 

  supply before installing, 

    removing, or adjusting any 

   

part or accessory on this tool, 

or before performing any maintenance on 

this tool.  Failure to do so could result in 

injury.  Whipping hoses can cause serious 

injury. Always check for and replace any 

damaged, frayed, or loose hoses and 

fittings. Do not operate a damaged or worn 

tool. Do not use quick­detach couplings at 

tool. See instructions for correct setup.

• Place the tool on the work 

 

  be fore start ing the tool. Do not point or 

  in dulge in any horse play with this tool.

   • 

Slipping, tripping and/or 

   

 falling while operating air 

   

  tools  can be a ma 

jor cause 

of se ri ous in ju ry or death. Be aware of 

ex cess hose left on the walk ing or work 

surface.

•  Keep body work 

ing stance bal 

anced 

  and firm. Do not over 

reach when 

 

op er at ing  the  tool.

•  Anticipate and be alert for sudden 

  changes in motion during use of any 

  power tool.

• Note direction of rotation BEFORE 

  operating  this tool.

   

• Do not carry tool by the hose.  

   

  Pro 

tect the hose from sharp  

   

  ob jects and heat.

   

• Tool shaft may con 

tin 

ue to 

 

 

  ro tate  brief ly  af ter  throt tle 

    is re 

leased. Avoid di 

rect 

con tact  with  ac ces so ries    dur ing  and  af ter 

use. Gloves will re duce the risk of cuts or 

burns.

     

• 

Keep away from ro 

tat 

ing 

    

end of tool. Do not 

Summary of Contents for 6-1138

Page 1: ...cias qu micas conocidas como agentes causantes del c ncer defectos de nacimiento y otros da os reproductivos Algunos ejemplos de dichas sustancias qu micas son plomo de pintura a base de plomo la sili...

Page 2: ...operate in spect and main tain this tool in ac cor dance with Amer i can Na tion al Stan dards In sti tute Safe ty Code of Por ta ble Air Tools ANSI B186 1 and any oth er ap pli ca ble safe ty codes a...

Page 3: ...e fumes and or water in the air line will cause damage to the tool Drain the air tank daily Clean the air inlet filter screen at least once per week The air inlet used for connecting the air supply ha...

Page 4: ...sy 1 116 RS1138116 Lock Nut 1 201 RS1138201 Packing Hammer Case 1 202 RS1138202 Thread Insert 4 203 RS1138203 Housing 1 204 RS1138204 Packing Hammer Case 1 Ref No Part No Description QTY 205 RS1138205...

Page 5: ...N Specifications Working Torque 300 1850 ft lbs Max Torque 2 000 ft lbs Free Speed 5 000 RPM Drive Size 1 Extended Anvil 8 Air Inlet 1 2 NPT Min Hose Size 3 4 I D Avg Air Cons 10 8 CFM Sound Level 108...

Page 6: ...SPINDLE DOESN T TURN OR TURNS ERRATICALLY This condition is probably caused by worn teeth on the ratchet or pawl a broken or weak pawl pressure spring or weak drag springs which fail to hold the spind...

Page 7: ...ma ingl s las instrucciones del producto y de seguridad le ser n le das y discutidas con el operador en el idioma materno del operador por parte del comprador propietario o su designado asegur ndose q...

Page 8: ...a vez por semana de manera constante La admisi n de aire que se ocupa para la conexi n del suministro de aire cuenta con una rosca americana est ndar de 1 4 NPT Se debe aumentar la presi n en la l nea...

Page 9: ...para tuercas de 1 USS Debe degradar el ndice para tuercas con resorte en U tuercas de montaje largos tornillos sin cabeza tuercas de doble profundidad para las condiciones de oxidaci n importante y pa...

Page 10: ...el anillo sujetador con las partes nuevas adecuadas Ver desglose Coloque el anillo sujetador en la mesa y presione al yunque de la herramienta en el anillo con un movimiento mecedor Con la mano cierr...

Page 11: ...tible probablemente se haya desencajada USTED DEBE reemplazar el anillo O ver desglose o llevar la herramienta a un centro autorizado de servicio para que se lleve a cabo el mantenimiento de ella MART...

Page 12: ...NAPA Para una lista completa de centros maestros de reparaci n autorizada consulte el formulario del cliente de reparaci n de garant a o visite www toolwarrantyrepair com DOBLE SU GARANT A Al registra...

Page 13: ...que l op rateur en comprend bien le contenu Veuillez toujours utiliser inspecter et entretenir cet outil conform ment au code de s curit ANSI sur les outils pneumatiques portatifs ANSI B186 1 et tout...

Page 14: ...r d air comprim tous les jours Nettoyez le filtre de l entr e d air au moins une fois par semaine La source d alimentation en air est raccord e une entr e d air ayant un filetage normalis NPT de 1 4 p...

Page 15: ...oulons de ressort en U de boulons d ancrage de longues vis d assemblage d crous double longueur de pi ces de fixation ressort ou d crous tr s rouill s car ceux ci absorbent la plus grande partie de la...

Page 16: ...externe rigide et une structure interne souple L action d un outil chocs muni d une telle douille endommage la prise et rend le serrage difficile Les douilles en chrome endommagent rapidement le mand...

Page 17: ...s l entr e d air Faites fonctionner l outil par saccades avec le burin en place et contre une surface solide D branchez la source d alimentation en air Tapez doucement sur le nez ou sur le corps de l...

Page 18: ...umatiques voyez le formulaire de r clamation en vertu de la garantie ci joint ou rendez vous au www toolwarrantyrepair com DOUBLEZ LA DUR E DE VOTRE GARANTIE Enregistrez votre outil l adresse www prop...

Reviews: