Rev.00 - 06.2021 | MAN PD30CTB IO-Link EN | © 2021 |
CARLO GAVAZZI Industr6
38
EN
7.2.3. SSC parameters
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Teach-In Select
58 (0x3A)
RW
1 = SSC1
0 = No Channel Selected
1 = SSC1 (Switching Signal Channel 1)
2 = SSC2 (Switching Signal Channel 2)
UIntegerT
8 bit
Teach-In Result
59 (0x3B)
-
-
-
-
-
Teach-in State
1 (0x01)
RO
0 = Idle
0 = Idle
1 =Success
4 = Wait for command
5 = Busy
7 = Error
RecordT
8 bit
TP1 (Teach Point 1) of
SP1 (Set point 1)
2 (0x02)
RO
0 = Not OK
0 = Not OK
1 = OK
RecordT
8 bit
TP2 (Teach Point 2) of
SP1 (Set point 1)
3 (0x03)
RO
0 = Not OK
0 = Not OK
1 = OK
RecordT
8 bit
TP1 (Teach Point 1) of
SP2 (Set point 2)
4 (0x04)
RO
0 = Not OK
0 = Not OK
1 = OK
RecordT
8 bit
TP2 (Teach Point 2) of
SP2 (Set point 2)
5 (0x05)
RO
0 = Not OK
0 = Not OK
1 = OK
RecordT
8 bit
SSC1 Parameter
(Switching Signal Channel 1)
60 (0x3C)
-
-
-
-
-
Set point 1 (SP1)
1 (0x01)
R/W
20 mm
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
IntegerT
16 bit
Set point 2 (SP2)
2 (0x02)
R/W
200 mm for PD30CTBx20...
250 mm for PD30CTBS25...
350 mm for PD30CTBR35...
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
IntegerT
16 bit
SSC1 Configuration
(Switching Signal Channel 1)
61 (0x3D)
-
-
-
-
-
Switching Logic
1 (0x01)
R/W
0 = High active
0 = High active
1 = Low active
UIntegerT
8 bit
Mode
2 (0x02)
R/W
1 = Single Point
0 = Deactivated
1 = Single Point
2 = Window
3 = Two Point
4 = FGS
UIntegerT
8 bit
Hysteresis
3 (0x03)
R/W
14 mm for PD30CTBx20...
17 mm for PD30CTBS25...
24 mm for PD30CTBR35...
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
UIntegerT
16 bit
SSC2 Parameter
(Switching Signal Channel 2)
62 (0x3E)
-
-
-
-
-
Set point 1 (SP1)
1 (0x01)
R/W
20 mm
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
IntegerT
16 bit
Set point 2 (SP2)
2 (0x02)
R/W
200 mm for PD30CTBx20...
250 mm for PD30CTBS25...
350 mm for PD30CTBR35...
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
IntegerT
16 bit
SSC2 Configuration
(Switching Signal Channel 2)
63 (0x3F)
-
-
-
-
-
Switching Logic
1 (0x01)
R/W
0 = High active
0 = High active
1 = Low active
UIntegerT
8 bit
Mode
2 (0x02)
R/W
1 = Single Point
0 = Deactivated
1 = Single Point
2 = Window
3 = Two Point
4 = FGS
UIntegerT
8 bit
Hysteresis
3 (0x03)
R/W
14 mm for PD30CTBx20...
17 mm for PD30CTBS25...
24 mm for PD30CTBR35...
20 ... 225 mm for PD30CTBx20...
20 ... 275 mm for PD30CTBS25...
20 ... 375 mm for PD30CTBR35...
UIntegerT
16 bit