Rev.00 - 06.2021 | MAN PD30CTB IO-Link EN | © 2021 |
CARLO GAVAZZI Industr6
16
EN
2.4.4.1.5. One shot leading edge
Each time a target is detected in front of the sensor the switching output generates a pulse of constant
length on the leading edge of the detection. This function is not retriggerable. See figure below.
N.O.
∆t
∆t
∆t
∆t
Presence of target
Example with normally open output
Example with normally open output
2.4.4.1.3. Turn Off delay (T-off)
The deactivation of the switching output is delayed until after to the time of removal of the target in the front
of the sensor, as like shown in the figure below.
Presence of
target
N.O.
Toff
Toff
Toff
Toff
Presence of target
2.4.4.1.4. Turn ON and Turn Off delay (T-on and T-off)
When selected, both the Ton and the Toff delays are applied to the generation of the switching output.
N.O.
Ton
Ton
Ton
Toff
Toff
Presence of target
Example with normally open output