Rev.00 - 06 .2021 | MAN PD30CTB IO-Link EN | © 2021 |
CARLO GAVAZZI Industri
39
EN
7.2.4. Output Parameters
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Channel 1 Setup (SO1)
64 (0x40)
-
-
-
-
-
Stage Mode
1 (0x01)
R/W
1 = PNP output
0 = Disabled output
1 = PNP output
2 = NPN output
3 = Push-pull output
UIntegerT
8 bit
Input selector 1
2 (0x02)
R/W
1 = SSC 1
0 = Deactivated
1 = SSC 1
2 = SSC 2
3 = Dust Alarm 1 (DA1)
4 = Dust alarm 2 (DA2)
5 = Temperature Alarm (TA)
6 = External logic input
7 = Application Functions
UIntegerT
8 bit
Timer Mode
3 (0x03)
R/W
0 = Disabled timer
0 = Disabled timer
1 = T-on delay
2 = T-off delay
3 = T-on/T-off delay
4 = One-shot leading edge
5 = One-shot trailing edge
UIntegerT
8 bit
Timer Scale
4 (0x04)
R/W
0 = Milliseconds
0 = Milliseconds
1 = Seconds
2 = Minutes
UIntegerT
8 bit
Timer Value
5 (0x05)
R/W
0
0 … 32 767
IntegerT
16 bit
Logic function
7 (0x07)
R/W
0 = Direct
0 = Direct
1 = AND
2 = OR
3 = XOR
4 = Set-reset Flip-Flop
UIntegerT
8 bit
Output Inverter
8 (0x08)
R/W
0 = Not inverted (Normally Open)
0 = Not inverted (Normally Open)
1 = Inverted (Normally Closed)
UIntegerT
8 bit
Channel 2 Setup (SO2)
65 (0x41)
-
-
-
-
-
Stage Mode
1 (0x01)
R/W
1 = PNP output
0 = Disabled output
1 = PNP output
2 = NPN output
3 = Push-Pull
4 = Digital logic input (Active high/
Pull-down)
5 = Digital logic input (Active low/
Pull-up)
6 = Teach-in (Active high)
UIntegerT
8 bit
Input selector 2
2 (0x02)
R/W
1 = SSC 1
0 = Deactivated
1 = SSC 1
2 = SSC 2
3 = Dust Alarm 1 (DA1)
4 = Dust alarm 2 (DA2)
5 = Temperature Alarm (TA)
6 = External logic input
7 = Application Functions
UIntegerT
8 bit
Timer Mode
3 (0x03)
R/W
0 = Disabled timer
0 = Disabled timer
1 = T-on delay
2 = T-off delay
3 = T-on/T-off delay
4 = One-shot leading edge
5 = One-shot trailing edge
UIntegerT
8 bit
Timer Scale
4 (0x04)
R/W
0 = Milliseconds
0 = Milliseconds
1 = Seconds
2 = Minutes
UIntegerT
8 bit
Timer Value
5 (0x05)
R/W
0
0 … 32 767
IntegerT
16 bit
Logic function
7 (0x07)
R/W
0 = Direct
0 = Direct
1 = AND
2 = OR
3 = XOR
4 = Set-reset Flip-Flop
UIntegerT
8 bit
Output Inverter
8 (0x08)
R/W
1 = Inverted (Normally Closed)
0 = Not inverted (Normally Open)
1 = Inverted (Normally Closed)
UIntegerT
8 bit