Rev.00 - 06 .2021 | MAN PD30CTB IO-Link EN | © 2021 |
CARLO GAVAZZI Industri
43
EN
7.2.7. Diagnostic parameters
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Sensor Diagnostics
Frontend Failure
209 (0xD1)
RO
0 = OK
0 = OK. 1 = Fail.
IntegerT
8 bit
EE_MemoryFailure (during
power up)
208 (0xD0)
-
-
-
-
-
Memory Failure
1 (0x01)
RO
0 = OK
0 = OK. 1 = Fail.
IntegerT
8 bit
Temperature Diagnostics
Maximum temperature
– All time high
203 (0xCB)
RO
- °C
-50 … 150 [°C]
IntegerT
16 bit
Minimum temperature
- All time low
204 (0xCC)
RO
- °C
-50 … 150 [°C]
IntegerT
16 bit
Maximum temperature since
power-up
205 (0xCD)
RO
- °C
-50 … 150 [°C]
IntegerT
16 bit
Minimum temperature since
power-up
206 (0xCE)
RO
- °C
-50 … 150 [°C]
IntegerT
16 bit
Current temperature
207 (0xCF)
RO
- °C
-50 … 150 [°C]
IntegerT
16 bit
Minutes above Maximum
Temperature
211 (0xD3)
RO
0 min
0 … 2 147 483 647 [min]
IntegerT
32 bit
Minutes below Minimum
Temperature
212 (0xD4)
RO
0 min
0 … 2 147 483 647 [min]
IntegerT
32 bit
Operating Diagnostics
Operating Hours
201 (0xC9)
RO
0 h
0 … 2 147 483 647 [h]
IntegerT
32 bit
Number of Power Cycles
202 (0xCA)
RO
0
0 … 2 147 483 647
IntegerT
32 bit
Detection counter SSC1
210 (0xD2)
RO
0
0 … 2 147 483 647
IntegerT
32 bit
Maintenance event counter
213 (0xD5)
RO
0
0 … 2 147 483 647
IntegerT
32 bit
Download counter
214 (0xD6)
RO
0
0 … 65 536
UIntegerT
16 bit
Quality of Teach
75 (0x4B)
RO
-
0 … 255
UIntegerT
8 bit
Quality of Run
76 (0x4C)
RO
-
0 … 255
UIntegerT
8 bit
Excess Gain
83 (0x53)
RO
-
1 … 255%
UIntegerT
8 bit
Error Count
32 (0x20)
RO
0
0 … 65 535
UIntegerT
16 Bit
Device Status
36 (0x24)
RO
0 = Device is operating properly
0 = Device is operating properly
1 = Maintenance required
2 = Out-of-specification
3 = Functional-Check
4 = Failure
UIntegerT
8 Bit
Detailed Device Status
37 (0x25)
-
-
-
-
-
Temperature fault
-
RO
-
-
OctetStringT
3 Byte
Temperature over-run
-
RO
-
-
OctetStringT
3 Byte
Temperature under-run
-
RO
-
-
OctetStringT
3 Byte
Short-circuit
-
RO
-
-
OctetStringT
3 Byte
Maintenance Required
-
RO
-
-
OctetStringT
3 Byte
Event Configuration
Event Configuration
74 (0x4A)
-
-
-
-
-
Maintenance event (0x8C30)
1 (0x01)
R/W
0 = Maintanance event Inactive
0 = Maintenance event Inactive
1 = Maintenance event Active
RecordT
16 bit
Temperature fault event
(0x4000)
2 (0x02)
R/W
0 = Temperature fault
event Inactive
0 = Temperature fault event Inactive
1 = Temperature fault event Active
RecordT
16 bit
Temperature over-run event
(0x4210)
3 (0x03)
R/W
0 = Temperature over-run
event Inactive
0 = Temperature over-run event Inactive
1 = Temperature over-run event Active
RecordT
16 bit
Temperature under-run event
(0x4220)
4 (0x04)
R/W
0 = Temperature under-run
event Inactive
0 = Temperature under-run event Inactive
1 = Temperature under-run event Active
RecordT
16 bit
Short circuit event (0x7710)
5 (0x05)
R/W
0 = Short circuit
event Inactive
0 = Short circuit event Inactive
1 = Short circuit event Active
RecordT
16 bit