Rev.00 - 06.2021 | MAN PD30CTB IO-Link EN | © 2021 |
CARLO GAVAZZI Industr6
42
EN
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Observation Menu
Pattern recognition
97 (0x61)
-
-
-
-
-
Timestamp 1 … 20
1 … 20
(0x01 … 14)
R/W
0
Time stamp for each event [ms].
Relative to start (time 0)
UIntegerT
16 bit
Pattern Timestamp 1 … 20
21 … 40
(0x15 … 28)
R/W
0 = No Edge
0 = No Edge
1 = Positive Edge
2= Negative Edge
UIntegerT
8 bit
Object Time Length
41 (0x29)
R/W
0 ms
0 … 65 535 ms
UIntegerT
16 bit
Reference pattern
42 (0x2A)
R/W
0 = Not Saved
0 = Not Saved
1 = Saved
UIntegerT
8 bit
Reference pattern No of
Edges
43 (0x2B)
R/W
0
0 … 20
UIntegerT
8 bit
7.2.6.2. Pattern Recognition (cont)
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Divider and counter Setup
93 (0x5D)
-
-
-
-
-
Counter limit
1 (0x01)
R/W
5
1 … 65 535
UIntegerT
16 bit
Preset counter value
2 (0x02)
R/W
0
-
0 … 65 535
UIntegerT
16 bit
Result
94 (0x5E)
-
-
-
-
-
Counter value
1 (0x01)
RO
-
0 … 65 535
UIntegerT
16 bit
7.2.6.3. Divider
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Object and Gap Monitoring
Setup
95 (0x5F)
-
-
-
-
-
Object minimum time
1 (0x01)
R/W
500 ms
10 … 60 000 ms
UIntegerT
16 bit
Object maximum time
2 (0x02)
R/W
10 000 ms
10 … 60 000 ms
UIntegerT
16 bit
Gap minimum time
3 (0x03)
R/W
500 ms
10 … 60 000 ms
UIntegerT
16 bit
Gap maximum time
4 (0x04)
R/W
10 000 ms
10 … 60 000 ms
UIntegerT
16 bit
Object and Gap Monitoring
Result
96 (0x60)
-
-
-
-
-
Object time
1 (0x01)
RO
0 ms
0 … 60 000 ms
UIntegerT
16 bit
Gap time
2 (0x02)
RO
0 ms
0 … 60 000 ms
UIntegerT
16 bit
Object status
3 (0x03)
RO
0 = Idle
0 = Idle
1 = Measurement running
2 = Inside limits
3 = Time too long
4 = Time too short
UIntegerT
8 bit
Gap status
4 (0x04)
RO
0 = Idle
0 = Idle
1 = Measurement running
2 = Inside limits
3 = Time too long
4 = Time too short
UIntegerT
8 bit
7.2.6.4. Object and Gap Monitoring