1. 99, EZ-66 & 102 Oil Nozzle Selections
(when appliance data is not available)
Table 1
Apply the guidelines below to select a nozzle when appliance-specific nozzle data is not avialable from the
manufacturer. See notes at end of table for application tips. 99FRD wrapped-shield air tubes are intended
only for approved applications in wet-base combustion chambers.
99FRD/EZ-66 Nozzle specifications — Standard air tubes
Brand
Spray
Angle &
pattern
Nozzle rating, GPH
0.50 to 0.75
0.85 to 3.00
Delevan
Hollow
60°A
•
•
Hollow
45°A
•
Solid
60°B
•
Hago
Hollow
60°H
•
Hollow
45°H
•
Semi-solid
45°SS
•
Semi-solid
60°SS
•
•
Solid
45°ES
•
Solid
60°ES
•
Monarch
Hollow
60°NS
•
Seimi-solid
45°AR
•
•
Semi-solid
60°AR
•
•
Solid
45°R
•
Solid
60°R
•
Steinen
Hollow
45°H
•
Hollow
60°H
•
•
99FRD/EZ-66 Nozzle specifications — Wrapped-shield air tubes
102CRD Nozzle specifications
Brand
Spray
Angle &
pattern
Nozzle rating, GPH
Brand
Spray
Angle &
pattern
Nozzle rating, GPH
0.50 to 3.00
2.00 to 3.50
3.00 to 4.50
Delavan
Hollow
60°A
•
Delavan
Solid
60°B
•
Hollow
70°A
•
Solid
70°B
•
Hago
Hollow
60°H
•
Solid
80°B
•
Hollow
70°H
•
Hago
Semi-solid
45°SS
•
Monarch
Hollow
60°NS
•
Semi-solid
60°SS
•
Hollow
70°NS
•
Delevan
Solid
70°B
•
Steinen
Hollow
60°H
•
Hago
Holow
45°H
•
Hollow
70°H
•
Semi-solid
45°SS
•
Semi-solid
70°Q
•
1. In general, all the nozzles shown above will burn well. However, in short combustion chambers, solid nozzles are not recommended because the flame may impinge on the back wall.
2. If the nozzle selected for a retrofit application results in a smoky fire, you can sometimes determine the best nozzle to use by observing the flame. To do this, slowly cover the air band slots with your fingers while
the burner is firing. The flame will begin to smoke in the area where there is more fuel than air. If the smoke begins on the outer edges, try a narrower or more solid nozzle spray pattern. If the flame begins to smoke
at the tips, try a wider or more hollow nozzle spray pattern.
3. For a packaged appliance application on which the burner has been tested, use the nozzle given in the appliance manufacturer's instructions or supplement for the best results.