CALIFORNIA PROPOSITION 65 WARNING
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
which are known to the State of California to cause cancer and birth defects or other reproductive harm.
For more information go to: www.P65Warnings.ca.gov
How to Replace a Conventional Burner with an Infrared Sear Burner
1. To install the optional infrared burner, begin by first removing the far left cooking grid, flame
stabilizing grid and heat zone divider. The Flame stabilizing grid will not be re-installed over the burner.
2. Remove the conventional burner by removing the cotter pin that holds it in place. The pin is located
on the bottom rear of the burner and is accessible from the outside rear of the grill. Use needle nose
plyers to remove the cotter pin. Once removed, remove the conventional burner.
3. Remove the crossfire panel. The crossfire panel is a downward U shaped channel located between the
burners towards the rear of the burners. The crossfire panel is removed by unscrewing the fastener
under the channel which holds it in place. The most commonly used fastener can be removed with a
metric #4 Allen wrench included with the sear burner.