We can assure you that the thorough reading of this manual will guarantee correct installation and safe
use of the product described.
WARNINGS
BEFORE INSTALLING OR HANDLING THE HUMIDIFIER PLEASE CAREFULLY READ AND FOLLOW THE INSTRUCTIONS AND SAFETY
STANDARDS DESCRIBED IN THIS MANUAL AND ON THE LABELS ATTACHED TO THE
humiFog
.
CAUTION: ALWAYS DISCONNECT THE MAIN POWER BEFORE OPENING OR SERVICING THE HUMIDIFIER!
This appliance has been designed exclusively to directly humidify in ducts and AHUs through the atomizing rack.
The quality of the water used affects the operation of this unit, so the
humiFog
must be supplied with treated water (Reverse Osmosis or Deionized).
The installation, use and maintenance operations must be carried out according to the instructions contained in this manual and on the labels applied
internally and externally.
IMPORTANT: BEFORE beginning installation:
Check for shipping damage to cartons. Mark the shipping waybill accordingly.
Open cartons and check for any hidden damage. Mark the shipping waybill accordingly.
Check packing slip to ensure all items have been received. Notify CAREL of any shortages or damaged parts.
You must notify CAREL
within 5 working days of any shortages.
The conditions of the environment and the power supply voltage must comply with the specified values listed on the data label in the
humidifier.
All other uses and modifications made to the humidifier that are not authorized by the manufacturer are considered incorrect, and the
manufacturer assumes no liability for the consequences of any such unauthorized use.
Please note that the humidifier contains powered electrical devices and high pressure components.
All service and/or maintenance operations must be performed by qualified personnel who are aware of the necessary precautions and are
capable of performing the operations correctly.
Disconnect the humidifier from the main power supply before accessing any internal parts.
The humidifier must be installed in accordance with all local and national standards.
The humidifier is made of metallic and plastic parts. All parts must be disposed of according to the local and national standards for waste
disposal
.
WARNING: Your humidifier requires water to operate. Do NOT mount it above materials or machinery that could be damaged if a leak
occurs. CAREL assumes no responsibility for consequential or inconsequential damage as a result of any leaks.
Disposal of the parts of the humidifier: The humidifier is made up of metallic and plastic parts. All parts must be disposed of according to the local
standards on waste disposal.
Warranty on materials: 2 years (from the date of production, excluding the consumable parts).
Summary of Contents for humiFog UA1K0HM00
Page 1: ...humiFog UA pressure atomizing 1000 5000 kg hr READ AND SAVE THESE INSTRUCTIONS ...
Page 33: ...34 of 55 Fig 11 a 11 4 1 Replacement parts for the hydraulics and drive assembly ...
Page 34: ...35 of 55 Replacement parts for the electrical panel Fig 11 b ...
Page 38: ...39 of 55 FOR PUMPING STATIONS UA1K8H 000 UA2K5H 000 for voltage 66 SERIES TSF BRASS ...
Page 39: ...40 of 55 FOR PUMPING STATIONS UA1K0H 001 UA1K8H 001 UA2K5H 001 for voltage 66 SERIES TSF SS ...
Page 40: ...41 of 55 FOR PUMPING STATIONS UA3K5H 000 UA5K0H 000 for voltage Emperor HT Brass ...
Page 41: ...42 of 55 FOR PUMPING STATIONS UA3K5H 001 UA5K0H 001 for voltage PARTS LIST KEZ36A ...
Page 44: ...45 of 55 11 6 Wiring Schematic Figure 11 c ...
Page 52: ...53 of 55 NOTES ...
Page 53: ...54 of 55 NOTES ...