"humiFog direct" +0300073EN rel. 1.4 - 29.03.2022
3.3 Cabinet part numbers
Fig. 3.b
The cabinets diff er in terms of fl ow-rate delivered by the pump, power
supply voltage/frequency, and the capacity to control one or two
atomisation racks, managed independently from each other.
U A _ _ _ D _ _ 0 1
D = 230 V 50 Hz
U = 120 V 60 Hz
1 = single zone
2 = double zone
040 = 40 l/h
080 = 80 l/h
050 = 50 l/h
090 = 90 l/h
Part numbers available:
UA040DD101
40 l/h, 230V 50Hz, single zone
UA040DD201
40 l/h, 230V 50Hz, two zones
UA080DD101
80 l/h, 230V 50Hz, single zone
UA080DD201
80 l/h, 230V 50Hz, two zones
UA050DU101
50 l/h, 120V 60Hz, single zone
UA050DU201
50 l/h, 120V 60Hz, two zones
UA090DU101
90 l/h, 120V 60Hz, single zone
UA090DU201
90 l/h, 120V 60Hz, two zones
Tab. 3.a
N.B. to manage the 230V - 60 Hz power supply a 230V-120V transformer
can be installed upstream and connected to the cabinet. The transformer
must be installed according to safety standards in force.
3.4 Hose part numbers
The high pressure hoses (OD = 10 mm, ID = 6.4 mm) are supplied by
Carel in diff erent lengths. The part numbers available are listed below.
All the hoses have with M16x1.5 female couplings with O-rings, ideal for
direct connection to the cabinet and the blower units without needing
to use sealants. Each hose kit includes an M16x1.5 nipple to be used for
coupling diff erent hoses together.
Stainless steel pipes can also be used to connect the blowers to the
cabinet. The recommended outside diameter is 10 mm. This solution is
the installer’s responsibility.
Carel recommends using hoses rather than pipes.
UAKT005014
High pressure hose, L = 0.5 m
UAKT010014
High pressure hose, L = 1.0 m
UAKT020014
High pressure hose, L = 2.0 m
UAKT050014
High pressure hose, L = 5.0 m
UAKT100014
High pressure hose, L = 10 m
UAKT200014
High pressure hose, L = 20 m
Tab. 3.b
3.5 Blower unit part numbers
Fig. 3.c
The blower units diff er based on the number of nozzles, the type of
nozzles (the nozzles are already pre-assembled in the factory), power
supply voltage/frequency and the direction of spray (front or two
directions).
D L A _ _ _ _ _ 0 0
D = 230 V 50 Hz
U = 120 V 60 Hz
Nozzle size:
0 = 1.45 l/h
1 = 2.8 l/h
2 = 4.0 l/h
F = single zone (front)
B = double zone (front/back)
Number of nozzle
Part numbers available:
P/N
230 V 50 Hz BLOWERS (CE)
DLA02DF000
Front blower 3.0 l/h (2 x 1.45 l/h nozzles) 230 V 50 Hz
DLA02DF100
Front blower 5.0 l/h (2 x 2.8 l/h nozzles) 230 V 50 Hz
DLA02DF200
Front blower 8.0 l/h (2 x 4.0 l/h nozzles) 230 V 50 Hz
DLA04DF000
Front blower 6.0 l/h (4 x 1.45 l/h nozzles) 230 V 50 Hz
DLA04DF100
Front blower 11.0 l/h (4 x 2.8 l/h nozzles) 230 V 50 Hz
DLA04DF200
Front blower 16.0 l/h (4 x 4.0 l/h nozzles) 230 V 50 Hz
DLA04DB000
Double blower 6.0 l/h (4 x 1.45 l/h nozzles) 230 V 50 Hz
DLA04DB100
Double blower 11.0 l/h (4 x 2.8 l/h nozzles) 230 V 50 Hz
DLA04DB200
Double blower 16.0 l/h (4 x 4.0 l/h nozzles) 230 V 50 Hz
DLA08DB000
Double blower 12.0 l/h (8 x 1.45 l/h nozzles) 230 V 50 Hz
DLA08DB100
Double blower 22.0 l/h (8 x 2.8 l/h nozzles) 230 V 50 Hz
DLA08DB200
Double blower 32.0 l/h (8 x 4.0 l/h nozzles) 230 V 50 Hz
Tab. 3.c
P/N
120 V 60 Hz BLOWERS
DLA02UF000
Front blower 3.0 l/h (2 1x .45 l/h nozzles) 120 V 60 Hz
DLA02UF100
Front blower 5.0 l/h (2 x 2.8 l/h nozzles) 120 V 60 Hz
DLA02UF200
Front blower 8.0 l/h (2x 4.0 l/h nozzles) 120 V 60 Hz
DLA04UF000
Front blower 6.0 l/h (4 x 1.45 l/h nozzles) 120 V 60 Hz
DLA04UF100
Front blower 11.0 l/h (4 x 2.8 l/h nozzles) 120 V 60 Hz
DLA04UF200
Front blower 16.0 l/h (4 x nozzles from 4.0l/h) 120 V 60 Hz
DLA04UB000
Double blower 6.0 l/h (4 x 1.45 l/h nozzles) 120 V 60 Hz
DLA04UB100
Double blower 11.0 l/h (4 x 2.8 l/h nozzles) 120 V 60 Hz
DLA04UB200
Double blower 16.0 l/h (4 x 4.0 l/h nozzles) 120 V 60 Hz
DLA08UB000
Double blower 12.0 l/h (8 x 1.45 l/h nozzles) 120 V 60 Hz
DLA08UB100
Double blower 22.0 l/h (8 x 2.8 l/h nozzles) 120 V 60 Hz
DLA08UB200
Double blower 32.0 l/h (8 x 4.0 l/h nozzles) 120 V 60 Hz
Tab. 3.d
Summary of Contents for DLAQ2DF100