MULTIPROTOCOL INTERFACE STANDARD OPERATION
5 6 7 8
GND
9
DO
DI
5 6 7 8
GND
CLS
9
RCP
RDP
1. Connecting to an access control device
2. Choosing the output protocol
3. Selecting the output voltage
4. Timer controlled operation
5. WIEGAND protocol (bit flow sequence)
6. ISO2 protocol (bit flow sequence)
7. SERIAL protocol (bit flow sequence)
8. Code truncation
9. Setting up additional functions
Attention:
Multiprotocol interface standard operation is enabled
by moving
J3
to position
1
.
1. Connecting to an access control device
WIEGAND or SERIAL protocol:
The physical connection between the access
control device and the
RCQ504/508W00
interface
is carried out at the following binding posts:
9
(DO),
8
(DI) and
6
(GND).
ISO2 protocol (magnetic stripe)
The physical connection between the access
control device and the
RCQ504/508W00
is
carried out at the following binding posts:
9
(RCP, "read clock pulse"),
8
(RDP, "read data
pulse"),
7
(CLS, "card loading signal") and
6
(GND).
2. Choosing the output protocol
The interface has 16 different
formats for communicating with
the access control device. 11 of
these formats are
WIEGAND
, one
is
ISO2, one
is
SERIAL
and 3 are
CARDIN
formats. They can be
selected using the dip-switch "
S1
".
To select the output protocol
proceed as follows:
- switch off the interface;
- set the dips following the table;
- press and hold down
P1
;
- switch on the interface which will sound one long
beep
.
The protocol has been set.
For a detailed description of the bit transmission
sequence consult paragraphs 4 - 5 - 6 and 7.
3. Selecting the output voltage
There are three different methods for choosing the output voltage for the
formats
WIEGAND
,
ISO2
and
SERIAL
:
1) 12 Vdc
output with jumper "
J4
" in position "
1
".
2) 5 Vdc
output with jumper "
J4
" in position "
2
".
3) TTL
Open collector output with jumper "
J4
"
in position "
3
"
(open contact).
Pos.1
Pos.2
Pos.3
Pos.1
Pos.2
Pos.3
Pos.1
Pos.2
Pos.3
DIP1 DIP2 DIP3 DIP4 PROTOCOL
ON OFF
OFF
OFF WIEGAND 26 BIT
ON OFF
ON
OFF WIEGAND 26 BIT SITE
ON OFF
ON
ON
WIEGAND 26 BIT SITE + CH
OFF ON
OFF
OFF WIEGAND 37 BIT
OFF ON
OFF
ON
WIEGAND 37 BIT + CH
OFF ON
ON
OFF WIEGAND 37 BIT SITE
OFF ON
ON
ON
WIEGAND 37 BIT SITE + CH
OFF OFF
ON
OFF WIEGAND 37 BIT D10302
OFF OFF
ON
ON
WIEGAND 37 BIT D10302 (BCD)
ON ON
OFF
OFF WIEGAND 50 BIT
ON ON
OFF
ON
WIEGAND 50 BIT + CH
OFF OFF
OFF
ON
ISO 2
ON ON
ON
ON
SERIAL
ON
ON
ON
OFF
CARDIN EXPANSION