25
Transponder reader function
- Move a master tag / card near to the remote transponder reader.
- Every 3 seconds the software will cycle through the channels that can be associated with the new tag/card accompanied by the sounding of the
buzzer as follows:
- Once you have chosen the channel remove the master tag / card from the reader. Within 10 seconds bring the tag/card to be memorised near to
the reader. The reader will sound a
beep
to confirm.
The code was accepted and the functions assigned.
5. Cancelling user codes locally
(this procedure it is possible to cancel a keypad / transponder reader user code).
Interface
- Move jumper
J2
on the interface to '
pos. 1
' then press button
P2
and hold down for at least 2 seconds.
- The buzzer
B1
will sound '
beep
' to confirm and during the procedure the red led
L1
will flash quickly.
- The user code cancellation procedure will be activated with a time out maximum of 30 seconds.
Keypad function
- Type the code to be cancelled into the
keypad
and press " ". The interface will sound a
beep
to confirm.
The code has been cancelled.
Transponder reader function
- Move the tag / card you want to cancel near to the transponder reader. The interface will sound a
beep
to confirm.
The code has been cancelled
If you have inserted an invalid code or used a tag that has not been memorised the interface will sound 5 consecutive beeps and if the
memory content is empty the interface will sound 10 beeps.
6. Cancelling user codes remotely
(using this procedure you may cancel a keypad, tag or card user without directly accessing the interface).
Keypad function
- Type into the keypad the sequence:
"# '
code to cancel
' #".
- The keypad will sound a two-second long
beep
with the
red
and
green
leds lit.
The code has been cancelled.
Transponder reader function
- Move a
master tag
close to the transponder reader and hold it there until the reader sounds
5 beeps
.
- Remove the master
tag
from the reader. Within 10 seconds bring the tag to be cancelled near to the reader.
- The reader will sound a
beep
to confirm.
3 sec
3 sec
3 sec
3 sec
3 sec
1 bip
2 bip
3 bip
4 bip
5 bip
CHA
CHB
CHC
CHD
DEL
Attention!
Cancellation will only be
possible if jumper "
J2
" is in
position
1
.
Summary of Contents for S504 Series