23
SYSTEM MANAGEMENT FUNCTIONS
1. Deleting the entire code memory content (users)
2. Setting the master code
3. Memorising user codes locally
4. Memorising user codes remotely
5. Cancelling user codes locally
6. Cancelling user codes remotely
7. Activating the user code
8. DKSTPT transponder reader setup
(*)
9. DKSDUALT keypad setup
(*)
1. Deleting the entire code memory content
(
this procedure will also cancel any memorised RADIO codes).
- Press and hold down the
P1
and
P2
buttons for more than 4 seconds on the interface, buzzer
B1
will beep.
- The led
L1
will remain lit for the entire duration of the deletion, which lasts for about 3 seconds.
- The led
L1
will flash for a few moments and then switch off and the buzzer
B1
will beep. Release the buttons.
2. Setting the master code
(The master code allows the user codes to be managed remotely).
Interface
- Move jumper
J2
on the interface to '
position 2
' then press and hold down the button
P1
for at least 2 seconds.
- Buzzer
B1
will
beep
and during the procedure leds
L1
and
L2
will flash slowly.
- The master code memorisation procedure will be activated with a time maximum of 30 seconds.
Keypad function
- Type the chosen numerical code into the keypad to enable access to the functions (max. 6 digits) and
press confirm " ". The interface will give confirmation by sounding a
beep
.
Transponder reader function
It is possible to memorise a maximum of 5 master transponder tags/cards to access the interface
remotely and manage user codes.
- On the interface, move the dips of '
S1
' to '
ON
' according to the table to select the memory locations.
- Move the tag near to the remote transponder reader, the interface will give confirmation by sounding a
beep
.
Important remarks
• In the interface STANDARD operating mode DKS codes do not need to be
memorised as they will be presented directly in output.
•
The maximum number of devices that can be connected to a single interface is limited
to three
.
(*)
If multiple DKSTPT or DKSDUALT devices are connected to the interface each of them must
be set up with different device addresses
.
dip 1 dip 2 dip 3 dip 4
memory
ON
OFF
OFF
OFF
location 1
OFF
ON
OFF
OFF
location 2
OFF OFF
ON
OFF
location 3
OFF OFF
OFF
ON
location 4
ON
ON
ON
ON
location 5
If you have inserted an invalid master code
the interface will sound 5 consecutive beeps.
Summary of Contents for S504 Series
Page 99: ...99 Notes...