18
“PROG/OK”
to return to
‘motions’
“PROG/OK”
to confirm
Press the arrows
to increase or
decrease the value
(max. 63)
* * * * * * * * * * * * * * *
* *
* SET CONTRAST *
* SEC. *
* *
* * * * * * * * * * * * * * *
26
“PROG/OK”
to return to
‘options’
OPTIONS
SAFETY DEVICES
MOTION
DISPLAY
REMOTE
PROGRAM
TB FI
FS CP
TA TD
TC TAL
00.000.007
CC2X24 V1.00
OPTIONS
SAFETY DEVICES
MOTION
DISPLAY
REMOTE
Arrow
to scroll
SEQUENTIAL COM.
OPEN-SHUT/
OPEN-STOP-SHUT
AUTO. RECLOSING
ON/OFF
PRE-FLASHING
ON/OFF
OPTIONS
SAFETY DEVICES
MOTION
DISPLAY
REMOTE
Arrow
to scroll
OPTIONS
SAFETY DEVICES
MOTION
DISPLAY
REMOTE
Arrow
to scroll
SEQUENTIAL COM.
OPEN-SHUT/
OPEN-STOP-SHUT
AUTO. RECLOSING
ON/OFF
PRE-FLASHING
ON/OFF
SEQUENTIAL COM.
OPEN-SHUT/
OPEN-STOP-SHUT
AUTO. RECLOSING
ON/OFF
PRE-FLASHING
ON/OFF
PRE-FLASHING
ON/OFF
WARNING LIGHTS
FIXED/
INTERMITTENT
INDICATOR LIGHT
FIXED/
INTERMITTENT
WARNING LIGHTS
FIXED/
INTERMITTENT
INDICATOR LIGHT
FIXED/
INTERMITTENT
PHOTOCELL INVERT
DURING CLOSING/
AND IN STOP
INDICATOR LIGHT
FIXED/
INTERMITTENT
PHOTOCELL INVERT
DURING CLOSING/
AND IN STOP
TEST FI
ON/OFF
PHOTOCELL INVERT
DURING CLOSING/
AND IN STOP
TEST FI
ON/OFF
TEST FS
ON/OFF
TEST FS
ON/OFF
GATE DELAY
DURING OPENING
ON/OFF
ELECTRIC LOCK
ON/OFF
TEST FI
ON/OFF
TEST FS
ON/OFF
GATE DELAY
DURING OPENING
ON/OFF
GATE DELAY
ON/OFF
ELECTRIC LOCK
ON/OFF
MEMO RADIO
ON/OFF
ELECTRIC LOCK
ON/OFF
REMOTE
ON/OFF
OUTPUT LC/CH2
RADIO CHANNEL/
COURTESY LIGHT
“PROG/OK”
to confirm
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
MEMO RADIO
ON/OFF
OUTPUT LC/CH2
COURTESY LIGHT/
RADIO CHANNEL
EXIT
“PROG/OK”
to change
the value
CONTACT TB
NC/8K2
CONTACT FI
NC/8K2
CONTACT FS
NC/8K2
CONTACT TB
NC/8K2
CONTACT FI
NC/8K2
CONTACT FS
NC/8K2
“PROG/OK”
to confirm
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
CONTACT TB
NC/8K2
CONTACT FI
NC/8K2
CONTACT FS
NC/8K2
“PROG/OK”
to change
the value
CONTACT FI
NC/8K2
CONTACT FS
NC/8K2
CONTACT CP
NC/8K2
“PROG/OK”
to change
the value
CONTACT FS
NC/8K2
CONTACT CP
NC/8K2
EXIT
“PROG/OK”
to return to
‘safety devices’
MOTOR SELECTION
BL824
CURRENT SENSOR
LEVEL 1...5
LIMITED OPENING
SETTING 1...5
MOTOR SELECTION
BL824
CURRENT SENSOR
LEVEL 1...5
LIMITED OPENING
SETTING 1...4
“PROG/OK”
to confirm
“PROG/OK”
to change
the value
MOTOR SELECTION
BL824
CURRENT SENSOR
LEVEL 1...5
LIMITED OPENING
SELECTION 1...4
“PROG/OK”
to change
the value
CURRENT SENSOR
LEVEL 1...5
LIMITED OPENING
SETTING 1...5
DIST. FROM CLOSE
STEPS 1...9
“PROG/OK”
to change
the value
“PROG/OK”
to change
the value
CONTRAST
0....63
REAR LIGHTING
ALWAYS ON/60/30 SEC.
EXIT
“PROG/OK”
to confirm
CONTRAST
0....63
REAR LIGHTING
ALWAYS ON/60/30 SEC.
EXIT
“PROG/OK”
to change
the value
CONTRAST
0....63
REAR LIGHTING
ALWAYS ON/60/30 SEC.
EXIT
“PROG/OK”
to return to
‘display’
Note: 1
Note: 2
Note: 3
Note: 3
Note: 6
Note: 7
Note: 8
Note: 9
The number of
manoeuvres
carried out by
the operator
arm and the
ECU model are
always shown
on the opening
screen of the
display.
The plug
symbol
indicates that the
ECU is working
off mains power.
The fully
charged battery
symbol
indicates that the
ECU is working
off battery power
at 100%.
75%
50%
25%
0%
Note: 4
Note: 5
ITALIANO
FRANÇAIS
ENGLISH
NEDERLANDS
DEUTSCH
ESPAÑOL
PROGRAM
TB FI
FS CP
TA TD
TC TAL
00.000.007
CC2X24 V1.00
press both arrows
simultaneously to enter
the language submenu
“PROG/OK” to confirm
Flashing on the display. You have to enter the programming mode to program the system.
During normal operation it indicates that the "automatic repositioning" procedure is about to
take place. In this case any commands received (
TA, TC, TAL or TD
) will automatically start
this procedure.
This happens when an N.C. contact is activated (
FI, FS, CP
) during encoder programming or
automatic repositioning. Once the passive state of the security devices has been reset the gate
will start moving again automatically. It also happens if a blackout occurs during programming.
Safety device test error. Check the condition of the safety devices and make sure that the
alarm cuts in when an obstacle interferes with the beam (indication white characters on a black
background). In case of anomalies replace the damaged safety device or bridge the contact
and deactivate the safety test (option menu).
This occurs when the programmer sends a command to the motor and nothing happens (motor
1/2
doesn't move). Check the Faston connections of motor
1/2
and the condition of the fuses
"
F3
", "
F4
" and then give another opening or closing command. If the motor still doesn't move
you are faced with either a mechanical problem or a problem with the programmer.
Encoder count error motor
1/2
. If this error occurs during normal motor operation it means
that there is a problem with one of the encoder signals. Check the relative connections and
carry out automatic repositioning.
Encoder direction error motor
1/2
: The gate movement direction is different from the encoder
setting (eg. the gate moves in the closing direction while the program is carrying out the
opening stage). Check motor
1/2
power supply connections.
Current sensor error motor
1/2
. When the gate is not moving this symbol means there is a
problem with the current sensor
1/2
.
Opening this contact will provoke a travel direction inversion during the closing stage and
during the opening stage.
If the sensor intervenes during the opening direction the gate inverts the travel direction immediately
and proceeds to the fully open position. If the sensor intervenes during the closing direction the gate
automatically inverts the travel direction of a few centimetres and then stops to free the obstacle.
Alarm indications
TB FI
FS CP
TA TD
TC TAL
PROGRAM
TB FI
FS CP
TA TD
TC TAL
OUT OF POS
TB FI
FS CP
TA TD
TC TAL
SAFETY ERROR
TB FI
FS CP
TA TD
TC TAL
STOP PROG
AUTO PROG
TB FI
FS CP
TA TD
TC TAL
ERROR MOT1/2
TB FI
FS CP
TA TD
TC TAL
ERROR ENC1/2
TB FI
FS CP
TA TD
TC TAL
ERROR DIR1/2
TB FI
FS CP
TA TD
TC TAL
ERROR SENS1/2
TB FI
FS CP
TA TD
TC TAL
ACT. SAFETY EDGE
TB FI
FS CP
TA TD
TC TAL
ACTIVE SENSOR
Press an arrow
key to enter the
main menu
LIMITED OPENING
SETTING 1...5
DIST. FROM CLOSE
STEPS 1...9
GATE DELAY
STEPS 0...9
DIST. FROM CLOSE
STEPS 1...9
GATE DELAY
STEPS 0...9
BRAKING ROOM
SETTING 1...3
BRAKING ROOM
SETTING 1...3
BRAKING SPEED
SETTING 1...3
PAUSE TIME
130 SEC.
BRAKING SPEED
SETTING 1...3
PAUSE TIME
130 SEC.
EXIT
“PROG/OK”
to confirm
Press the arrows to increase or
decrease the value (max. 240 sec).
Keeping the arrows held down will
force the value to scroll rapidly.
* * * * * * * * * * * * * * *
* *
*
PAUSE TIME
*
*
SEC.
*
* *
* * * * * * * * * * * * * * *
180
GATE DELAY
STEPS 0...9
BRAKING ROOM
SETTING 1...3
BRAKING SPEED
SETTING 1...3
“PROG/OK”
to change
the value
Note: 10
“PROG/OK”
to change
the value
Note: 11
“PROG/OK”
to change
the value
Note: 12
Language choice:
• Press the right and left buttons simultaneously to enter the language submenu.
• Press the right and left buttons to change the language: Italian to English.
• Press the "PROG/OK" button to confirm the choice.
Pause time programming or pause for
automatic reclosing (if activated)
Automatic programming under way
Opening stage
Block during opening
Closing stage
Block during closing
Operational indications
TB FI
FS CP
TA TD
TC TAL
PAUSE
TB FI
FS CP
TA TD
TC TAL
AUTO PROG
TB FI
FS CP
TA TD
TC TAL
OPENING
TB FI
FS CP
TA TD
TC TAL
STOP OPENING
TB FI
FS CP
TA TD
TC TAL
CLOSING
TB FI
FS CP
TA TD
TC TAL
STOP CLOSING
“PROG/OK”
to confirm
PRESS the
transmitter
channel
to memorise
PRESS the
the same
transmitter
channel
again
“PROG/OK”
to confirm
Arrow
to scroll
ENCODING: S4XX
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
“PROG/OK”
to confirm
OPTIONS
SAFETY DEVICES
MOTION
DISPLAY
CALENDAR
REMOTE
MEMORISE
[Nr...]
* * * * * * * * * * * * * * *
* *
* ACTIVATION 1 *
* *
* * * * * * * * * * * * * * *
MEMORISE
[Nr...]
* * * * * * * * * * * * * * *
* *
* ACTIVATION 2 *
* *
* * * * * * * * * * * * * * *
MEMORISE
[Nr...]
* * * * * * * * * * * * * * *
* *
* CODE *
*
MEMORISED
*
* * * * * * * * * * * * * * *
“PROG/OK”
to confirm
CANCEL
[Nr...]
* * * * * * * * * * * * * * *
* *
* ACTIVATION 1 *
* *
* * * * * * * * * * * * * * *
PRESS the
transmitter
channel
to memorise
CANCEL
[Nr...]
* * * * * * * * * * * * * * *
* *
* ACTIVATION 2 *
* *
* * * * * * * * * * * * * * *
PRESS the
the same
transmitter
channel
again
CANCEL
[Nr...]
* * * * * * * * * * * * * * *
* *
* CODE *
*
CANCELLED
*
* * * * * * * * * * * * * * *
ENCODING: S4XX
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
“PROG/OK”
to confirm
* * * * * * * * * * * * * * *
* CANCEL *
* ALL MEMORY ? *
* * * * * * * * * * * * * * *
PRESS ok to
cancel all
memory
or press exit
ENCODING: S4XX
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
Arrow
to exit
EXIT
OK
* * * * * * * * * * * * * * *
* CANCELLING *
* * * * * * * * * * * * * * *
ENCODING: S4XX
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
CHANNEL A
channel function A
CHANNEL
B
channel function B
CHANNEL C
channel function C
CHANNEL D
channel function D
EXIT
ENCODING: S4XX
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
“PROG/OK”
to change
the value
ENCODING: S4XX
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
“PROG/OK”
to toggle the
value between
S4XX & S500
“PROG/OK”
to return to
the remote
menu
[AB--]
[AB--]
[AB--]
[AB--]
[AB--]
[AB--]
Note: 14
Note: 13
• All the functions of the electronic programmer can be set in the Display menu "
LCD1
" using the three buttons contained therein:
- use the arrows to navigate through the menu and/or to adjust the display contrast;
- use
"PROG/OK"
to modify the parameter settings and/or to confirm.
PROGRAMMING PROCEDURE (parameter setting)
Notes
:
1)
The indicator light
flashes slowly during opening, rapidly during closing; remains lit when the gate is blocked but not completely closed
and is off when the gate is completely closed.
2)
FI Mode:
-
FI
also active when the gate is blocked: If the photocells are in alarm and the gate is blocked, no movement commands will be accepted
(even opening commands);
-
FI
active only during closing: In both cases activating the
FI
safety device during the closing stage will force travel direction inversion.
3)
Photocell test (FI/FS)
If you enable the security test you will have to connect both the transmitter and the receiver to the controlled load output
(
CTRL 24 Vdc
). When the test is enabled one second will pass between receiving a command and carrying it out.
4)
Opening direction gate delay
If you enable gate delay the following will occur: during the opening movement gate leaf 1 moves first and then gate leaf 2. In the closing
direction gate leaf 2 moves first then gate leaf 1. If gate delay is disabled both gate leaves move simultaneously.
5)
Electric lock
If the electric lock is enabled the ELS output (binding post 8) will be activated before gate leaf 1 moves and will remain active until gate leaf
1 has moved a few centimetres.
6)
Select the type of motor
BL3924ERB = articulated (reversible)
BLi924
= inside operator
HL2524ESB = underground motor (HL1824/2524)
BL824
= articulated
BLi1000 = inside operator
BLTOW24 = articulated
BL224E
= straight arm
BL1924ASW = articulated
BL3924ESB = articulated (self-locking)
BLEGOS = straight arm
(BLEGOS/BLESOL)