Page 2: ...al día la presente publicación todas las modificaciones que considere oportunas para el perfeccionamiento técnico o para cualquier otro tipo de exigencia de carácter constructivo o comercial FAAC S p A Via Benini 1 40069 Zola Predosa BO ITALIA Tel 051 6172411 Tlx 521087 Fax 051 758518 FAAC per la natura La presente istruzione è realizzata al 100 in carta riciclata Non disperdete nell ambiente gli ...

Page 3: ...ve 89 392 EEC and subsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendments 92 31 EEC and 93 68 EEC and furthermore declares that unit must not be put into service until the machineryintowhichitisincorporatedorofwhichitisacomponenthasbeen identified...

Page 4: ...h on the supply line to the automation with a contact opening distance of 3 mm or more We recommend the use of a 6A thermal magnetic circuit breaker with multi pole switching 13 Ensure that a residual current device with a trip threshold of 0 03A is installed upstream of the automation system 14 Checkthattheearthingsystemisinstalledcorrectlyandisefficient Connectthemetalpartsofthegateandthe yellow...

Page 5: ...ion IP 55 Max thrust traction force daN 620 620 620 775 465 465 465 Rod stroke mm 260 260 260 260 260 380 380 Rod speed cm s 1 1 1 0 75 1 5 1 5 1 5 Operator weight Kg 8 6 8 6 8 6 8 6 8 6 10 10 Duty cycle cycles hour 70 70 70 60 80 50 50 Pump delivery l min 1 1 1 0 75 1 5 1 5 1 5 Operating pressure bar 40 40 40 50 30 30 30 Hydraulic locking 1 2 2 2 Maximum leaf length m 2 20 2 20 4 7 2 20 2 20 2 50...

Page 6: ...vided 4 Release the operator see paragraph 5 5 Extend the rod to the end of its stroke and then retract it by Table 2 INSTALLATIONDIMENSIONS about 5 mm Fig 5 6 Lock the operator see paragraph 6 7 Fit the front bracket onto the rod as shown in Fig 6 ref 2 8 Close the gate leaf and keeping the operator perfectly horizontal locate the leaf attachment position of the front bracket Fig 7 9 Fix the fron...

Page 7: ...e sheath 3 Fig 11 13 Repeattheaboveoperationstoinstallthesecondoperator 14 Maketheelectricalconnectionsoftheelectroniccontrolunit followingtheinstructionsprovided 4 START UP Fig 7 Fig 7 Fig 9 4 1 ANTI CRUSHING SYSTEM ADJUSTMENT The 400 automation is equipped with an anti crushing system which limits the torque applied by the operator when the gate leaf encounters an obstacle during its movement Wh...

Page 8: ...ition on the side of the operator Fig 12 Carefullycheckoperationoftheoperatorandalltheconnected accessories especiallythesafetydevices Give thecustomerthe Userguide anddemonstratehowtouse the operator correctly Point out the potential danger zones of the automated unit 5 MANUAL OPERATION In the event of a power failure or malfunction the gate can be operated manually by opening the sliding cover a...

Page 9: ...itted with one or more electric locks to ensure mechanical locking of the gate leaves The FAAC 400 can automate gate leaves up to 7 m in length depending on the model The operators are controlled by an electronic control unit housed in an enclosure which assures adequate protection against atmospheric agents Theleavesarenormallyclosed Whentheelectroniccontrolunit receivesanopencommandfromtheremote...