15
IMPORTANT REMARKS
IMPORTANT REMARKS
IMPORTANT REMARKS
• These instructions are aimed at professionally qualified "
installers
of electrical equipment
" and must respect the local standards and
regulations in force. All materials used must be approved and must suit
the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has
been made. "i.e.
for the automation of hinged gates
" with one or two
gate leaves;
- maximum gate length
2 m
(
2,5
m with an electric lock)
- maximum gate weight
200 kg
.
- minimum column width
180 mm
.
• The unit may be fitted both to the
right
and to the
left
of the passageway.
This product and all its relative components has been designed
and manufactured by Cardin Elettronica who have verified that
the product conforms in every aspect to the safety standards in
force. Any non authorised modifications are to be considered
improper dangerous and the complete responsibility of the installer.
Caution!
mechanical stop buffers must be installed in both the
closing and opening positions.
It is the responsibility of the installer to make sure that the following public
safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the
main road to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property at a height
between
1,5
and
1,8 m
and not on the public side of the gate. The gates
must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore
controls must be situated in a position where the operator
can see the gate at all times.
5) At least two warning signs (similar to the example on the
right) should be placed, where they can be easily seen by
the public, in the area of the system of automatic operation. One inside
the property and one on the public side of the installation. These signs
must be indelible and not hidden by any objects (such as tree branches,
decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must not
be allowed to play within the area of a gate installation. If possible include
this in the warning signs.
7) Whenever a fully open gate leaf comes within
at 500 mm
of a fixed
structure the space must be protected by an anticrush buffer.
8) You are advised to protect the system's lateral access points with pairs
of (
FS
) photocells connected to the stop input, see installation example,
component 13 on page 3.
9) If you have any questions about the safety of the gate operating system,
do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
•
200/BLTOW24M
self-locking
Master
reduction unit with an incorporated
encoder, onboard electronics and aluminium operator arm.
•
200/BLTOW24S
self-locking
Slave
reduction unit with an incorporated
encoder without onboard electronics complete with aluminium operator
arm.
- Direct current drive motor
24 Vdc
.
- Permanently lubricated double worm screw reduction unit. Externally
activated manual release system managing the release of the gears form
the gate (emergency manoeuvre).
- A plastic framework is fixed to the reduction unit chassis and houses the
electronic programmer, the toroidal transformer and the radio frequency
module. The battery charger and special Cardin emergency
NiMH
batteries are optional.
- Motor support base in cast aluminium.
Attention!
Only for EU customers -
WEEE marking
.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differential
collection site for electronic and electrical goods or to send it
back to the manufacturer if the intention is to replace it with a new
equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials. Illicitly disposing of this
product by the owner is punishable by law and will be dealt with according
to the laws and standards of the individual member nation.
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred using
the supplied release key (see manual release page 7).
Periodically check the moving parts for wear and tear and grease if required
using lubricants which maintain their friction levels unaltered throughout time
and are suitable for temperatures of
-20 to +70°C
.
Periodically check the correct operation of all safety devices (photoelectric
cells etc.). The appliance is not suitable for continuous operation and must
be adjusted according to the model (see technical data on page 48).
The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children and
outside the opening range of the gate.
Before starting the installation of the system check that the structure which
is to be automated is in good working order and respects the local standards
and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of
-20 to +70°C
.
• Check the safety measures between the fixed and moving parts:
- a minimum space of
30 mm
must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the
pavement never exceeds
30 mm
throughout the entire opening angle of
the gate.
• The surface of the gate must not feature openings which allow a person’s
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order
(the upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example fig.1 pag. 2).
• Check that the appliance is suitable for the size, weight and duty cycle
of the gate to which it is to be applied (see duty cycle on page 48)
ASSEMBLY PROCEDURE
The unit may be positioned either to the
right
or to the
left
of the passageway:
• Move the gate/s to the closed position.
• Choose the value "
A
" according to the required opening angle (fig. 3) and
work out (depending on the structural characteristics of the gate) at what
height the front bracket "
Q
" will be fitted to the gate. Once the position
has been established, fasten the galvanised steel base "
D
" (fig. 5) using
4 M8 screws and 4 Ø14 steel rawlplugs (not supplied) making sure that
the steel base is perfectely square.
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
USER INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
WARNING