Component replacement and adjustment procedure
7.14
Probe Temperature substitution
Figure1
1.
Disconnect the power supply cord and remove the Oven
from the cabinet.
2.
Remove the upper cover.
3.
Remove the internal components cover
(fig 1)
by its six
screws.
4.
Remove the probe from its location using a clamp make
rounded the border to extract it
(fig.2).
5.
Disconnect the terminals
(fig.3).
6.
Replace the new one by reversing the previous steps
7.
Connect the terminals and insert the temperature probe,
crushing the entrance to make oval it to prevent the escape.
8.
The connections must not be loose.
9.
Reinstall the Oven into the cabinet.
10.
Reconnect the power supply cord after the Oven is installed.
11.
Run the Oven and check all functions and microwave
emission
(section 1.2).
Figure 2
Figure 3