Component replacement and adjustment procedure
7.8
Magnetron Substitution
1.
Disconnect the power supply cord and remove the
Oven from the cabinet.
2.
Remove the upper cover.
3.
Remove the internal component cover
(fig 1)
by its
six screws.
4.
Remove the cooling channel
(fig 2)
by its two screws.
5.
Disconnect from electrical supply magnetron
6.
Remove the thermal cutout located on the top of
Magnetron .
(fig.3).
7.
Now remove the Magetron from oven structure
unscrewing the four screws of its support.
(fig.3).
8.
Replace the new one by reversing the previous
steps.
Figure 1
NOTE: When remove the
magnetron, be sure to install
the magnetron gasket in the
correct position and be sure
that the gasket is in good
condition.
ATTENTION! not touch the
magnetron antenna it can be
damage.
9.
Connect the electrical connector and reassemble the
thermal cutout.
10.
The connections must not be loose.
11.
Reinstall the Oven into the cabinet.
12.
Reconnect the power supply cord after the Oven is
installed.
13.
Run the Oven and check all functions and microwave
emission
(section 1.2).
Figure 2