Capacity of Texas, Inc.
68
171
{3}
Ambient Air Temperature
Sensor 1 Circuit - Voltage
Above Normal or Shorted to
High Source. High signal
voltage detected at ambient air
temperature circuit.
None on performance.
98
{2}
Engine Oil Level - Data
Erratic, Intermittent, or In-
correct. An intermittent signal
is being received from the oil
level sensor.
Oil level sensor operation will
be disabled.
98
{1}
Engine Oil Level - Data Valid
But Below Normal
Operational Range - Most
Severe Level. Very low oil
level has been detected by the
oil level sensor.
The engine may derate.
Possible low oil pressure.
Possible severe engine
damage.
171
{4}
Ambient Air Temperature
Sensor 1 Circuit - Voltage
Below Normal or Shorted to
Low Source. Low voltage
detected at ambient air
temperature circuit.
None on performance.
1347
{4}
Fuel Pump Pressurizing
Assembly 1 Circuit - Volt- age
Below Normal or Shorted to
Low Source. Low signal
voltage detected at the fuel
pump actuator circuit.
Engine will run poorly at idle.
Engine will have low power.
Fuel pressure will be higher
than commanded.
1347
{3}
Fuel Pump Pressurizing
Assembly 1 Circuit - Volt- age
Above Normal or Shorted to
High Source. High signal
voltage or open circuit
detected at the fuel pump
actuator circuit.
Engine will
not
run or engine
will run poorly.
639
{9}
SAE J1939 Multiplexing PGN
Timeout Error - Abnormal
Update Rate. The ECM
expected information from a
multiplexed device but did
not
receive it soon enough or did
not
receive it at all.
One or more multiplexed
devices will
not
operate
properly. One or more
symptoms will occur.
Table 4-3 CM2150 System Fault Codes (Cont.)
Fault
Code
Reason
Effect
Summary of Contents for TJ5000 DOT
Page 2: ......
Page 8: ......
Page 21: ...Trailer Jockey Operators Handbook 13 Figure 2 2 Dash LED Indicators ...