46
102
{3}
Intake Manifold Pressure
Sensor Number 1 Circuit-
Shorted High. High signal
voltage detected at the Intake
Manifold Pressure Circuit.
Engine power derate.
102
{4}
Intake Manifold Pressure
Sensor Number 1 Circuit-
Shorted Low. Low signal
voltage detected at the Intake
Manifold Pressure Circuit.
Engine power derate.
91
{3}
Accelerator Pedal/Lever
Position Sensor Circuit -
Shorted High. High signal
voltage detected at the
Accelerator Pedal/Lever
Position Circuit.
Severe derate in power output
of the engine. Limp home
power
only
.
974
{3}
Remote Throttle Pedal/Lever
Position Sensor Circuit -
Shorted High. High signal
voltage detected at the Remote
Accelerator Pedal/Lever
Position Circuit.
Remote accelerator will
not
operate. Remote accelerator
position will be set to zero
percent.
974
{4}
Remote Throttle Pedal/Lever
Position Sensor Circuit -
Shorted Low. Low signal
voltage detected at the remote
Accelerator Pedal/Lever
Position Circuit.
Remote accelerator will
not
operate. Remote accelerator
position will be set to zero
percent.
110
{3}
Engine Coolant Temperature
Sensor Circuit - Shorted High.
High signal voltage detected at
the Engine Coolant
Temperature Sensor Circuit.
Possible white smoke. Fan will
stay ON if controlled by the
ECM. No engine protection for
engine coolant temperature.
110
{4}
Engine Coolant Temperature
Sensor Circuit- Shorted Low.
Low signal voltage detected at
the Engine Coolant
Temperature Sensor Circuit.
Possible white smoke. Fan will
stay ON if controlled by the
ECM. No engine protection for
engine coolant temperature.
Table 4-2 CM850 System Fault Codes (Cont.)
Fault
Code
Reason
Effect