206
According to the setting item, you can specify parameters using modifier “% characters”.
Note
• A runtime error will occur if the specified name does not match.
• If this modifier is not defined, “%” will be deleted.
Modifiers
Modifiers
Meaning
Description of character string entered
%n
Reason for capture (number)
0 (test) |
1 (External device input 1) | 2 (External device input 2) |
1 (External device input) |
33 (Timer 1) | 34 (Timer 2) | 35 (Timer 3) | 36 (Timer 4) | 145 (Volume detection) | 146 (Scream
Detection) | 161 (Intelligent Function Detection Setting 1) |
162 (Intelligent Function Detection Setting 2) | 163 (Intelligent Function Detection Setting 3) |
164 (Intelligent Function Detection Setting 4) | 165 (Intelligent Function Detection Setting 5) |
166 (Intelligent Function Detection Setting 6) | 167 (Intelligent Function Detection Setting 7) |
168 (Intelligent Function Detection Setting 8) | 169 (Intelligent Function Detection Setting 9) |
170 (Intelligent Function Detection Setting 10) | 171 (Intelligent Function Detection Setting 11) |
172 (Intelligent Function Detection Setting 12) | 173 (Intelligent Function Detection Setting 13) |
174 (Intelligent Function Detection Setting 14) | 175 (Intelligent Function Detection Setting 15) |
201 (Linked Event 1) | 202 (Linked Event 2) | 203 (Linked Event 3) | 204 (Linked Event 4)
%N
Reason for capture
(character string)
<External input device name (alphanumeric characters) > |
Intelligent Function Detection Setting name (alphanumeric characters) |
NULL (blank entry or interval timer test)
%O
Reason for capture (ON/OFF)
OFF | ON
%X
Width of image
Number of pixels in horizontal direction
%Y
Height of image
Number of pixels in vertical direction
%C
Camera number
1
%D
Camera Name
Setting for [Camera Name (alphanumeric characters)]
%P
Pan position
-180.00 – 180.00
0
%T
Tilt position
-90.00 – 90.00
0
%Z
Zoom position
0.01 – 300.00
%R
Rotation position
0
%V
Camera server
VB-H45/VB-M44/VB-H730F Mk II/VB-S30D Mk II/VB-S31D Mk II/VB-S800D Mk II/
VB-S900F Mk II/VB-S805D Mk II/VB-S905F Mk II
%y
Year of capture time
2001 – 2031
%m
Month of capture time
01 – 12
%d
Day of capture time
01 – 31
%w
Day of week of capture time
0 – 6 (Sunday to Saturday)
%H
Hours of capture time
00 – 23
%M
Minutes of capture time
00 – 59
%S
Seconds of capture time
00 – 59
%s
Milliseconds of capture time
000 – 999
%z
Time zone of capture time
-1200 – +1300
%a
Weekday name of capture
time
Sun | Mon | Tue | Wed | Thu | Fri | Sat
%b
Month name of capture time
Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec
%h
Host Name
HM4x H730
S30 S31 S80x S90x
HM4x S30 S31
H730 S80x S90x
HM4x S30 S31
H730 S80x S90x
Summary of Contents for VB-R13VE H2
Page 44: ...26 ...
Page 54: ...36 ...
Page 92: ...74 ...
Page 244: ...226 Reset Switch LED LED Reset Switch H730 S30 S31 S80x S90x Reset Switch LED ...
Page 260: ...BIE 7197 000 CANON INC 2017 ...