COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SUPER G3FAX BOARD-J1 REV.0 JUNE 2001
CHAPTER 6 ERROR CODES
6-9
##674 (transmission)
At time of V.34 transmission, the procedure fails to move from
phase 3 or phase 4 to control channel, causing a T1 time-out
and releasing the line.
Cause:
In phase 3 or phase 4, the line of the receiving side is cut or the signal of
the receiving side cannot be detected.
Remedy:
Use service data #1 SSSW SW28 bit 0 to prohibit the V.8/V.34 procedure of
the caller.
Use service data #2 MENU No. 07 to increase the transmission level within
the range between -8 and -15 dBm.
##675 (reception)
At time of V.4 reception, the procedure fails to move from
phase 3 or phase 4 to control channel, causing a T1 time-out
and releasing the line.
Cause:
In phase 3 or phase 4, the line of the transmitting side is cut or the signal of
the transmitting side cannot be detected.
Remedy:
Use service data #1 SSSW SW28 bit 1 to prohibit the V.8/V.34 procedure of
the caller.
Use service data #2 MENU No. 07 to increase the transmission level in the
range between -8 and -15 dBm.