MultiPASS C755 Chapter 3: Maintenance & Service
7.2.7 Faculty tests
The faculty tests are selected by pressing the
6
button from the test mode menu. These tests test the
following faculties of this fax.
Test type
Overview
Sensor tests
Test whether the sensors are operating correctly.
Operation panel test
Tests whether the button switches on the control panel are
operating correctly.
Line signal reception test
Tests whether the NCU board signal sensor and frequency
counter are operating correctly.
a) Sensor tests
The sensor test is selected by pressing the
3
button from the faculty test menu. In this test, you can
check the status of each sensor of this fax in item 1 on the display.
You can also check if sensors that use actuators and microswitches are operating correctly by moving
the actuator or microswitch. (See page 3-33 Faulty scanner unit’s sensors.)
The sensor tests cannot be used to test all of the sensors. The following sensors cannot be
tested with the sensor tests:
Home position sensor, pickup roller sensor, cover sensor, and ink detection
sensor.
If any of these sensor are faulty, an error message or service error code will appear to
indicate the faulty sensor.
NOTE
Summary of Contents for MultiPASS C755
Page 1: ...MultiPASS C755 SERVICE MANUAL Canon ...
Page 4: ...III III REVISION HISTORY REVISION CONTENT 0 Original ...
Page 51: ...2 24 MultiPASS C755 Chapter 2 Assembly and Disassembly This page intentionally left blank ...
Page 64: ...3 13 MultiPASS C755 Chapter 3 Maintenance Service This page intentionally left blank ...
Page 114: ...3 63 MultiPASS C755 Chapter 3 Maintenance Service Figure 3 31 Print Pattern Sample ...
Page 139: ...3 88 MultiPASS C755 Chapter 3 Maintenance Service This page intentionally left blank ...