c) V.34 G3 signal transmission test
The V.34 G3 signal transmision test menu is selected by pressing the 8 key from the MODEM NCU test
menu. The V.34 G3 signals below are sent from the modem using the modular jack and the speaker by
pressing the start key.
The Baud rate can be changed with the numeric keys, and the Speed can be changed with the search
keys.
Numeric key
Baud rate
0
3429 baud
1
3200 baud
2
3000 baud
3
2800 baud
4
2743 baud (Not used)
5
2400 baud
Search key
Speed
2400 bps–2.4 kbps
4800 bps–4.8 kbps
7200 bps–7.2 kbps
9600 bps–9.6 kbps
12000 bps–12.0 kbps
14400 bps–14.4 kbps
16800 bps–16.8 kbps
19200 bps–19.2 kbps
21600 bps–21.6 kbps
24000 bps–24.0 kbps
26400 bps–26.4 kbps
28800 bps–28.8 kbps
31200 bps–31.2 kbps
33600 bps–33.6 kbps
The transmission level for each frequency follows the service data.