Laser Exposure System
■ After Replacing the Laser Scanner Unit
1. Register values indicated on the label packaged with the Laser Scanner Unit in the following service mode items.
• COPIER > ADJUST > SCNR > SUB-S-Y0 (Laser output correction value, vertical scanning irradiation position0 Y)
• COPIER > ADJUST > SCNR > SUB-S-M0 (Laser output correction value, vertical scanning irradiation position0 M)
• COPIER > ADJUST > SCNR > SUB-S-C0 (Laser output correction value, vertical scanning irradiation position0 C)
• COPIER > ADJUST > SCNR > SUB-S-K0 (Laser output correction value, vertical scanning irradiation position0 K)
• COPIER > ADJUST > SCNR > SUB-S-Y1 (Laser output correction value, vertical scanning irradiation position1 Y)
• COPIER > ADJUST > SCNR > SUB-S-M1 (Laser output correction value, vertical scanning irradiation position1 M)
• COPIER > ADJUST > SCNR > SUB-S-C1 (Laser output correction value, vertical scanning irradiation position1 C)
• COPIER > ADJUST > SCNR > SUB-S-K1 (Laser output correction value, vertical scanning irradiation position1 K)
• COPIER > ADJUST > SCNR > SUB-S-Y2 (Laser output correction value, vertical scanning irradiation position2 Y)
• COPIER > ADJUST > SCNR > SUB-S-M2 (Laser output correction value, vertical scanning irradiation position2 M)
• COPIER > ADJUST > SCNR > SUB-S-C2 (Laser output correction value, vertical scanning irradiation position2 C)
• COPIER > ADJUST > SCNR > SUB-S-K2 (Laser output correction value, vertical scanning irradiation position2 K)
• COPIER > ADJUST > SCNR > MAI-S-Y0 (Laser output correction value, horizontal scanning irradiation position0 Y)
• COPIER > ADJUST > SCNR > MAI-S-M0 (Laser output correction value, horizontal scanning irradiation position0 M)
• COPIER > ADJUST > SCNR > MAI-S-C0 (Laser output correction value, horizontal scanning irradiation position0 C)
• COPIER > ADJUST > SCNR > MAI-S-K0 (Laser output correction value, horizontal scanning irradiation position0 K)
• COPIER > ADJUST > SCNR > MAI-S-Y1 (Laser output correction value, horizontal scanning irradiation position1 Y)
• COPIER > ADJUST > SCNR > MAI-S-M1 (Laser output correction value, horizontal scanning irradiation position1 M)
• COPIER > ADJUST > SCNR > MAI-S-C1 (Laser output correction value, horizontal scanning irradiation position1 C)
• COPIER > ADJUST > SCNR > MAI-S-K1 (Laser output correction value, horizontal scanning irradiation position1 K)
• COPIER > ADJUST > SCNR > MAI-S-Y2 (Laser output correction value, horizontal scanning irradiation position2 Y)
• COPIER > ADJUST > SCNR > MAI-S-M2 (Laser output correction value, horizontal scanning irradiation position2 M)
• COPIER > ADJUST > SCNR > MAI-S-C2 (Laser output correction value, horizontal scanning irradiation position2 C)
• COPIER > ADJUST > SCNR > MAI-S-K2 (Laser output correction value, horizontal scanning irradiation position2 K)
2. After values are registered, affix the label [1] packaged with the unit on the inside [2] of the right cover.
[1]
[2]
5. Adjustment
239
Summary of Contents for MF720 Series
Page 1: ...Revision 2 0 MF720 Series Service Manual...
Page 12: ...Product Overview 1 Product Lineups 5 Product Features 7 Specifications 8 Name of Parts 14...
Page 79: ...4 Click Import Export Import 1 2 2 Technical Explanation 71...
Page 103: ...Durable Parts No durable parts is set for this product 3 Periodical Service 95...
Page 104: ...Periodical Services No periodical service is set for this product 3 Periodical Service 96...
Page 232: ...Adjustment 5 Overview 225 Adjustment at Parts Replacement 226...
Page 248: ...Troubleshooting 6 Test Print 241 Trouble shooting items 243 Version Upgrade 244 Debug Log 248...
Page 258: ...Error Jam Alarm 7 Outline 251 Error Codes 252 Jam Code 257...
Page 267: ...Service Mode 8 Overview 260 COPIER 264 FEEDER 300 FAX 302 TESTMODE 308...
Page 322: ...APPENDICES Service Tools 315 General Circuit Diagram 316 Print Sequence 317 Backup Data 318...