9.12.7 CR_TEMPFAIL COMMAND
COMMAND “CR_TEMPFAIL”[CR]
Details
Get the temperature inside a projector.
When some temperature sensors are installed in the projector, it is possible to
know the temperature all at once.
Acceptable
“000_%1_%2_%3”[CR]
%1
%2
%3
%1
=
Temperature, sensor 1
%2
=
Temperature, sensor 2
%3
=
Temperature, sensor 3
(Ex.) “_31.5
F
”[CR]
_means a space. When the temperature sinks to -, the first
character “-” like “-05.5
F
”[CR].
Last character indicates the sensor’s status.
Exceeding critical temperature
=
”F”
Sensor temperature is safe
=
”S”
Not relate to the temperature
=
”N”
“_31.5F”indicates 31.5 degrees and safety temperature.
When the temperature is safe, the data will be “
□
00.0S”.
Every time the projector is reset, “
□
00.0S”is set.
In short, previous data is deleted.
Response
Unacceptable “
?
”[CR]