![background image](http://html.mh-extra.com/html/canon/lv-7555/lv-7555_specifications_62526052.webp)
MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
9.12.4 CR_PTIMER COMMAND
COMMAND “CR_PTIMER”[CR]
Details
Get Presentation Timer status
Acceptable
“000_%1”[CR]
%1
“ON”------- Presentation timer is active
“STOP”--- Presentation timer is pause
“OFF”----- Presentation timer is inactive
Response
Unacceptable “
?
”[CR]
9.12.5 CR_INFPFAIL COMMAND
COMMAND “CR_INFPFAIL”[CR]
Details
Get the power failure status.
Data is shown in 32bits HEX
Normal
=
ALL HI(FF)
Abnormal
=
ALL LO(00)
Acceptable
“000_%1”[CR]
%1
“********”
Show 32bits hexadecimal numeral in 8 figures
:
“FFFFFFFF”
=
All are normal
Response
Unacceptable “
?
”[CR]
9.12.6 CR_TEMPWARN COMMAND
COMMAND
“CR_TEMPWARN”[CR]
Details
Get if the sensors are exceeding or approaching critical temperature. When
some sensors are installed inside the projector, get each sensor’s
temperature.
Acceptable
“000_%1_%2_%3”[CR]
%1
%2
%3
%1…temperature sensor 1
%2…temperature sensor 2
%3…temperature sensor 3
“W”--- Exceeding critical temperature(Warning)
“S”--- Sensor temperature is safe.
“N”--- Not relate to the temperature
Ex. When “S_W_S”[CR] means that sensor 1 is saftety
temperature, sensor 2 is exceeding critical temperature,
and sensor 3 is safety temperature.
Note)Depends on projector models, when the temperature
difference between sensor 1 and sensor 2 is over the specified
temperature, the sensor may show “W”. In this case, sensor
3 shows that the temperature difference is “W”, “S”, or “N”.
Response
Unacceptable “
?
”[CR]
Page 52 / 53