Technology > Embedded RDS > FAQ
Technology > Embedded RDS > FAQ
No.9
Q: How does E-RDS operate while the device is placed in the sleep mode?
A: While being in Real Deep Sleep, and if data to be sent is in E-RDS, the system wakes up
asleep, then starts to send the data to the UGW. The system also waits for completion of data
transmission and let the device to shift to asleep status again.
However, transition time to the Real Deep Sleep depends on the device, and the transition to
sleep won't be done if the next data transmission will be done within 10 minutes.
No.10
Q: Is E-RDS compatible with Section counter (Department counter)?
A: No, E-RDS does not support Section counter.
No.11
Q: Is there any setting to be made on the device side to enable the service mode menu
transmission function? Moreover, what is Service mode menu set as the object of
transmission?
A: No steps peculiar to Transmitting Service mode menu.
Following Service mode data will be sent to UGW at each event mentioned below.
Transmission timing
Transmitting data
Error retry
When the following alarm is detected.
Alarm codes for transmission:
0x060002, // Fixing
0x060004 - 0x069999, // Fixing
0x090005 - 0x099999, // Dram
0x100006 - 0x109999, // Development
0x300001 - 0x309999 // High voltage
COPIER
DISPLAY
ANALOG
No
HV-STS
CCD
DPOT
DENS
FIXING
SENSOR
MISC
HT-C
HV-TR
P-PASCAL
When the following service call error is detected.
Error codes for transmission:
E000 - E00F, // Fixing
E020, // Development ATR
E060 - E06F // High voltage
COPIER
DISPLAY
ANALOG
No
HV-STS
CCD
DPOT
DENS
FIXING
SENSOR
MISC
HT-C
HV-TR
P-PASCAL
Transmission timing
Transmitting data
Error retry
When a value is set to [COPIER - ADJUST]
subordinate’s Service mode menu.
(Transmission will be done at 60 min, later of
setting)
COPIER
ADJUST
Yes
When the first communication test is done.
COPIER
DISPLAY
ANALOG
No
HV-STS
CCD
DPOT
DENS
FIXING
SENSOR
MISC
HT-C
HV-TR
P-PASCAL
ADJUST
NOTE:
Target transmission data are only the items under LEVEL1 and 2 in the service mode.
No.12
Q: What service browser data is transmitted to UGW by E-RDS in what timing?
A: The service browser data to be transmitted and the transmission timing are shown below.
Transmission timing
Detailed procedure
Transmission
information
Error occurs
When operation is
performed to enable service
browsing*
(Only when the operation to
enable service browsing is
performed in the condition
where [disabling:OFF] is set)
1) Make service browser
settings in the service
mode menu.
2) Send browser
information to UGW.
3) When OK is received
from UGW, set
"enabling: 1: Active".
(To use the setting, it is
necessary to reboot the
device)
Service browser mode:
[Register]
WEB browser
option: [ON] or [OFF]
according to the
license status
Retransmission
is not
performed. The
service browser
mode is not
enabled.
("Disabling
[OFF]"
continues to be
set.)
T-2-119
Summary of Contents for imageRUNNER ADVANCE 6055 Series
Page 4: ...Blank Page ...
Page 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Page 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Page 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...