Technology > Fixing > Controls > Fixing temperature control
Technology > Fixing > Controls > Fixing temperature control
●
Temperature Control for Standby
To provide measures against temperature rise of the coil/Main Body and save energy
consumption, the target temperature is reduced step by step on a specified time basis until it
reaches a certain temperature.
190
185
180
1
5
10
Fixing Roller
temperature(deg C)
Time(min)
F-2-133
The control temperature depends on the environment temperature/country. The details on the
control temperature are shown below.
• Normal environment 17 degC or higher
Destination
Model
Time (minute)
0 to 1
1 to 5
5 to 10
10 and
longer
Japanese
imageRUNNER ADVANCE 6075
185
180
175
170
mageRUNNER ADVANCE 6065
185
180
175
170
imageRUNNER ADVANCE 6055
180
175
170
170
Non Japanese imageRUNNER ADVANCE
6075/6065/6055
190
185
180
175
• Low temperature environment Lower than 17 degC
Destination
Model
Time (minute)
0 to 5
5 to 10
10 to 20
20 and
longer
Japanese
imageRUNNER ADVANCE
6075/6065/6055
190
185
180
175
Non Japanese imageRUNNER ADVANCE
6075/6065/6055
195
190
185
180
NOTE:
When restoring from the recovery mode, temperature control is conducted from the
2nd line of temperature control table.
T-2-59
T-2-60
Summary of Contents for imageRUNNER ADVANCE 6055 Series
Page 4: ...Blank Page ...
Page 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Page 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Page 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...