5. Remove the guide plate (two screws).
4512U009AB
6. Remove the cover (two screws).
4512U010AB
7. Remove the cover (two screws).
4512U011AA
8. Install the Sensor Unit to the cover that has
been removed in step 7 following the order
shown in the illustration (by fitting tabs of the
Sensor Unit into slits in the cover).
9. Slightly press the Sensor Unit in the direction
shown by the arrow.
4512U012AC
1
2
3
10. Withdraw the connector of the Sensor Unit
through the hole shown in the illustration.
11. Open the cord clamp.
12. Connect the connector and close the cord
clamp.
4512U028AB
13. Reinstall the cover (two screws).
4512U014AA
14. Press the Flat Spring against the Finisher
Unit and install it (one screw).
4512U015AB
15. Insert the Punch Unit.
16. Temporarily secure the Punch Unit (one
screw).
4512U016AA