7–10
SERVICE MODE
Fault
Separation delay
Separation
Different number
of originals after
jam removal
Original pulled
Original size
Sensor
PI1, PI2
PI1, PI2
PI7
PI1
PI1, PI7
Condition
Both the original sensor (PI1) and the registration sen-
sor (PI2) do not turn on within 2 sec after the main
motor (M1) has turned on.
Both the original sensor (PI1) and the registration sen-
sor (PI2) do not turn ON 2 sec after the main motor
(M1) has turned ON. (1st original only)
The last original is detected before feeding the number
of originals identified by the jam recovery mechanism.
The original sensor (PI1) is OFF after pick-up opera-
tion (other than the last original).
The original sensor (PI1) turns OFF for such originals
as may be the last original (A5R, A4, B6R, B5,
STMTR, LTR), but the detected original is not the last
original.
Code
02H
03H
11H
13H
14H
Note: The number in parentheses under the Code column is in decimal notation.
• ALARM (ADF)
PI1: ...Original sensor
PI2: ...Registration sensor
PI7: ...Original length sensor (S)
PI2
PI1
PI7
Summary of Contents for GP215
Page 4: ......
Page 36: ......
Page 38: ...3 2 TROUBLESHOOTING IMAGE PROBLEMS ...
Page 39: ...3 3 TROUBLESHOOTING IMAGE PROBLEMS ...
Page 40: ...3 4 B Image Fault Samples ...
Page 80: ......
Page 92: ...6 6 ARRANGEMENT AND FUNCTIONS OF ELECTRICAL PARTS C Fans Figure 6 603 FM6 FM5 FM2 FM3 FM1 FM4 ...
Page 105: ...6 19 ARRANGEMENT AND FUNCTIONS OF ELECTRICAL PARTS 3 Composite Power Supply PCB Figure 6 610 ...
Page 204: ...C GENERAL CIRCUIT DIAGRAM General Circuit Diagram 1 4 A 3 ...
Page 205: ...General Circuit Diagram 2 4 A 4 ...
Page 206: ...General Circuit Diagram 3 4 A 5 ...
Page 207: ...General Circuit Diagram 4 4 A 6 ...